Energy and Exergy Efficiency Analysis of Fluid Flow and Heat Transfer in Sinter Vertical Cooler

Zude Cheng, Haitao Wang, Junsheng Feng, Yongfang Xia and Hui Dong
Additional contact information
Zude Cheng: School of Environment and Energy Engineering, Anhui Jianzhu University, Hefei 230601, China
Haitao Wang: School of Environment and Energy Engineering, Anhui Jianzhu University, Hefei 230601, China
Junsheng Feng: School of Environment and Energy Engineering, Anhui Jianzhu University, Hefei 230601, China
Yongfang Xia: School of Environment and Energy Engineering, Anhui Jianzhu University, Hefei 230601, China
Hui Dong: School of Metallurgy, Northeastern University, Shenyang 110819, China

Energies, 2021, vol. 14, issue 15, 1-18

Abstract: In order to fully understand the energy and exergy transfer processes in sinter vertical coolers, a simulation model of the fluid flow and heat transfer in a vertical cooler was established, and energy and exergy efficiency analyses of the gas–solid heat transfer in a vertical cooler were conducted in detail. Based on the calculation method of the whole working condition, the suitable operational parameters of the vertical cooler were obtained by setting the net exergy efficiency in the vertical cooler as the indicator function. The results show that both the quantity of sinter waste heat recovery (SWHR) and energy efficiency increased as the air flow rate (AFR) increased, and they decreased as the air inlet temperature (AIT) increased. The increase in the sinter inlet temperature (SIT) resulted in an increase in the quantity of SWHR and a decrease in energy efficiency. The air net exergy had the maximum value as the AFR increased, and it only increased monotonically as the SIT and AIT increased. The net exergy efficiency reached the maximum value as the AFR and AIT increased, and the increase in the SIT only resulted in a decrease in the net exergy efficiency. When the sinter annual production of a 360 m 2 sintering machine was taken as the processing capacity of the vertical cooler, the suitable operational parameters of the vertical cooler were 190 kg/s for the AFR, and 353 K for the AIT.

Keywords: sinter; vertical cooler; gas–solid heat transfer; energy efficiency; exergy efficiency (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/14/15/4522/pdf (application/pdf)
https://www.mdpi.com/1996-1073/14/15/4522/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:14:y:2021:i:15:p:4522-:d:602043

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:14:y:2021:i:15:p:4522-:d:602043