Energies, 2021, vol. 14, issue 17, 1-13

Abstract: In this work, numerical simulation calculations were performed to investigate the minimum ground temperature that occurs when extracting thermal energy in a horizontal ground heat exchanger system in the Central European climate. The influence of ground thermal conductivity, heat flux extracted from the ground, periodic interruptions in the operation of the heat exchanger, periodic supply of heat energy to the ground, relative humidity of the ambient air, evaporation rate coefficient, and convective heat transfer coefficient on the ground minimum temperature were investigated. Based on the simulation, it was found that the high value of ground thermal conductivity favorably affects the operation of the installation with a ground heat exchanger. Both the reduction of the maximum heat flux taken from the ground, as well as periodic interruptions in the operation of the exchanger effectively protects the ground against excessive cooling. Further, it was found that heat supply to the ground in summer only slightly raises its minimum temperature, as well as the decrease of the relative humidity of the ambient air and evaporation rate coefficient. The change of the convective heat transfer coefficient has no significant impact on the minimum annual ground temperature.

Keywords: ground temperature; heat extraction; ground heat exchanger; heat pump (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (3)

Downloads: (external link)
https://www.mdpi.com/1996-1073/14/17/5487/pdf (application/pdf)
https://www.mdpi.com/1996-1073/14/17/5487/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:14:y:2021:i:17:p:5487-:d:628035

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:14:y:2021:i:17:p:5487-:d:628035