SCADA Data-Based Working Condition Classification for Condition Assessment of Wind Turbine Main Transmission System
Huanguo Chen,
Chao Xie,
Juchuan Dai,
Enjie Cen and
Jianmin Li
Additional contact information
Huanguo Chen: Faculty of Mechanical Engineering and Automation, Zhejiang Sci-Tech University, Hangzhou 310018, China
Chao Xie: Faculty of Mechanical Engineering and Automation, Zhejiang Sci-Tech University, Hangzhou 310018, China
Juchuan Dai: School of Mechanical Engineering, Hunan University of Science and Technology, Xiangtan 411201, China
Enjie Cen: Hangzhou Dingchuan Information Technology Co., Ltd., Hangzhou 310016, China
Jianmin Li: Faculty of Mechanical Engineering and Automation, Zhejiang Sci-Tech University, Hangzhou 310018, China
Energies, 2021, vol. 14, issue 21, 1-18
Abstract:
Due to the complex and variable conditions under which wind turbines operate, existing working condition classification methods are inadequate for condition assessment of the main transmission system. Because working conditions are too few after classification, it cannot effectively describe the complex and variable working conditions of wind turbine. This can lead to high false-alarm rates in the condition monitoring, which affect normal operations. This paper proposes a working condition classification method for the main transmission system of wind turbines based on supervisory control and data acquisition (SCADA) data. Firstly, correlation analysis of SCADA data acquired by wind farm is used to select the parameters relevant to the main transmission system. Secondly, according to the wind turbine control principle, the working conditions are initially divided into four phases: shutdown, start-up, maximum wind energy tracking, and constant speed. The k -means clustering algorithm is used to subdivide the maximum wind energy-tracking phase and constant speed phase, which account for a larger proportion of the working conditions, to achieve better classification. Finally, a case study is used to demonstrate the calculation of alarm thresholds and alarm rates for each working condition. The results are compared with the direct use of k -means clustering for working condition classification. It is concluded that the proposed method can significantly reduce the false-alarm rate of the vibration detection process.
Keywords: main transmission system; working conditions classification; wind turbine working characteristics; alarm threshold; k -means clustering; SCADA data (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (2)
Downloads: (external link)
https://www.mdpi.com/1996-1073/14/21/7043/pdf (application/pdf)
https://www.mdpi.com/1996-1073/14/21/7043/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:14:y:2021:i:21:p:7043-:d:666418
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().