EconPapers    
Economics at your fingertips  
 

Investigation of Home Energy Management with Advanced Direct Load Control and Optimal Scheduling of Controllable Loads

Kanato Tamashiro, Talal Alharbi, Alexey Mikhaylov, Ashraf M. Hemeida, Narayanan Krishnan, Mohammed Elsayed Lotfy and Tomonobu Senjyu
Additional contact information
Kanato Tamashiro: Fuculty of Engineering, University of the Ryukyus, 1 Senbaru, Nishihara-cho, Nakagami, Okinawa 903-0213, Japan
Talal Alharbi: Department of Electrical Engineering, College of Engineering, Qassim University, Buraydah 52571, Saudi Arabia
Ashraf M. Hemeida: Fuculty of Energy Engineering, Awan University, Aswan 81711, Egypt
Narayanan Krishnan: Department of Electrical and Electronics Engineering, SASTRA Deemed University, Thanjavur 613401, India
Mohammed Elsayed Lotfy: Fuculty of Engineering, University of the Ryukyus, 1 Senbaru, Nishihara-cho, Nakagami, Okinawa 903-0213, Japan
Tomonobu Senjyu: Fuculty of Engineering, University of the Ryukyus, 1 Senbaru, Nishihara-cho, Nakagami, Okinawa 903-0213, Japan

Energies, 2021, vol. 14, issue 21, 1-14

Abstract: Due to the rapid changes in the energy situation on a global scale, the amount of RES installed using clean renewable energy sources such as Photovoltaic (PV) and Wind-power Generators (WGs) is rapidly increasing. As a result, there has been a great deal of research aimed at promoting the adoption of renewable energy. Research on Demand-side Management (DSM) has also been important in promoting the adoption of RES. However, the massive introduction of PV has changed the shape of the demand curve for electricity, which significantly impacts the operational planning of thermal generators. Therefore, this paper proposes an Advanced Direct Load Control (ADLC) model to temporarily shutdown the electric connection between the power grid and Smart Houses (SHs). The most important feature of the proposed model is that it temporarily shuts down the electric connection with the power grid. The shutdown is performed twice to increase the load demand during daytime hours and reduce the peak load during night-time hours. The proposed model also promotes the self-consumption of the generated power during the shutdown period, which is expected to reduce the operating cost. This paper considers six case studies for SH, and the operational costs and carbon dioxide emissions are compared and discussed. The results show that the SH with ADLC successfully reduces the operating costs and carbon dioxide emissions.

Keywords: smart house; renewable energy; heat pump; advanced direct load control (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/1996-1073/14/21/7314/pdf (application/pdf)
https://www.mdpi.com/1996-1073/14/21/7314/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:14:y:2021:i:21:p:7314-:d:671881

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-22
Handle: RePEc:gam:jeners:v:14:y:2021:i:21:p:7314-:d:671881