Operational Analysis of Fire Alarm Systems with a Focused, Dispersed and Mixed Structure in Critical Infrastructure Buildings
Krzysztof Jakubowski,
Jacek Paś,
Stanisław Duer and
Jarosław Bugaj
Additional contact information
Krzysztof Jakubowski: National Cyber Security Centre, Gen. Buka 1, 05-119 Legionowo, Poland
Jacek Paś: Division of Electronic Systems Exploitations, Faculty of Electronics, Institute of Electronic Systems, Military University of Technology, 2 Gen. S. Kaliski St., 00-908 Warsaw, Poland
Stanisław Duer: Department of Energy, Faculty of Mechanical Engineering, Technical University of Koszalin, 15-17 Raclawicka St., 75-620 Koszalin, Poland
Jarosław Bugaj: Division of Radiocommunication, Faculty of Electronics, Institute of Communications Systems, Military University of Technology, 2 Gen. S. Kaliski St., 00-908 Warsaw, Poland
Energies, 2021, vol. 14, issue 23, 1-24
Abstract:
The article presents issues regarding the impact of operating conditions on the functional reliability of representative fire alarm systems (FASs) in selected critical infrastructure buildings (CIB). FAS should operate correctly under variable environmental conditions. FASs ensure the safety of people and CIB. Operational measurements for 10 representative systems were conducted in order to determine the impact of environmental conditions on FAS reliability. Selected operational indices were also determined. The next stage involved developing two models of representative FASs and the availability, pre-ageing time and operating process security indices. Determining operational indices is a rational selection of FAS technical and organizational solutions that enables the reliability level to be increased. Identifying the course of the FAS operating process security hazard changes in individual system lines, particularly at the initial operation stage, enables people that supervise the operation to affect operating parameters on an ongoing basis. The article is structured in the following order: issue analysis, FAS power supply in CIB, operational test results, selected FAS operating process models, determination of operational and security indices, and conclusions.
Keywords: fire alarm system; critical infrastructure; reliability requirements; construction facilities (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (5)
Downloads: (external link)
https://www.mdpi.com/1996-1073/14/23/7893/pdf (application/pdf)
https://www.mdpi.com/1996-1073/14/23/7893/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:14:y:2021:i:23:p:7893-:d:687276
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().