Varying VAWT Cluster Configuration and the Effect on Individual Rotor and Overall Cluster Performance
Jeffrey E. Silva and
Louis Angelo M. Danao
Additional contact information
Jeffrey E. Silva: Energy Engineering Graduate Program, University of the Philippines Diliman, Quezon City 1101, Philippines
Louis Angelo M. Danao: Department of Mechanical Engineering, University of the Philippines Diliman, Quezon City 1101, Philippines
Energies, 2021, vol. 14, issue 6, 1-22
Abstract:
The effect of separation distance between turbines on overall cluster performance were simulated using computational fluid dynamics software and we found that at a distance equivalent to two rotors, there was an improvement of +8.06% in the average performance of the cluster compared to a single, isolated turbine. A very small improvement in performance was noted at the equivalent distance of 12 rotor diameters. The performances of three individual turbines in pyramid- and inverted pyramid-shaped vertical axis wind turbine clustered farm configurations with varying oblique angles at a fixed spacing of two equivalent rotor diameters were also investigated. The design experiment involves the simulation of test cases with oblique angles from 15° to 165° at an interval of 15° and the turbines were allowed to rotate through 18 full rotations. The results show that the left and right turbines increase in performance as the angle with respect to the streamline axis increases, with the exception of the 165° angle. The center turbine, meanwhile, attained its maximum performance at a 45° oblique angle. The maximum cluster performance was found to be in the configuration where the turbines were oriented in a line (i.e., side by side) and perpendicular to the free-stream wind velocity, exhibiting an overall performance improvement of 9.78% compared to the isolated turbine. Other array configurations show improvements ranging from 6.58% to 9.57% compared to the isolated turbine, except in the extreme cases of 15° and 165°, where a decrease in the cluster performance was noted due to blockage induced by the left and right turbines, and the center turbines, respectively.
Keywords: CFD; clustered wind farms; VAWT (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (9)
Downloads: (external link)
https://www.mdpi.com/1996-1073/14/6/1567/pdf (application/pdf)
https://www.mdpi.com/1996-1073/14/6/1567/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:14:y:2021:i:6:p:1567-:d:515555
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().