Effect of Phase Change Materials on the Thermal Performance of Residential Building Located in Different Cities of a Tropical Rainforest Climate Zone
Almas Sheriyev,
Shazim Ali Memon,
Indira Adilkhanova and
Jong Kim
Additional contact information
Almas Sheriyev: Department of Civil and Environmental Engineering, School of Engineering and Digital Sciences, Nazarbayev University, Nur-Sultan 010000, Kazakhstan
Shazim Ali Memon: Department of Civil and Environmental Engineering, School of Engineering and Digital Sciences, Nazarbayev University, Nur-Sultan 010000, Kazakhstan
Indira Adilkhanova: Department of Civil and Environmental Engineering, School of Engineering and Digital Sciences, Nazarbayev University, Nur-Sultan 010000, Kazakhstan
Jong Kim: Department of Civil and Environmental Engineering, School of Engineering and Digital Sciences, Nazarbayev University, Nur-Sultan 010000, Kazakhstan
Energies, 2021, vol. 14, issue 9, 1-22
Abstract:
This study aims to investigate the thermal performance of PCM and PCM combined with nighttime natural (NV) and mechanical ventilation (MV) applied to a residential building located in eight cities of tropical rainforest climate zone (Af). The analysis was accomplished using numerical simulations and developing a unique methodology for selecting the PCM melting temperature based on the thermal comfort limits. The thermal performance of the PCM integrated building was quantitatively evaluated using the concept of peak temperature drop. Additionally, a novel indicator of Total Temperature Drop ( TTD ) was introduced to determine the overall impact of the PCM and PCM combined with NV/MV on the thermal comfort conditions inside the building. The results showed that PCM 28 was the most efficient in improving the thermal performance of the building located in the Af climate zone, achieving a TTD of up to 356 °C per year. The usage of PCM 28 combined with nighttime natural ventilation improved the TTD values by up to 15%, whereas the integration of PCM 28 combined with mechanical ventilation resulted in a TTD values increase of up to 45%. Conclusively, mechanical ventilation showed its superiority over natural ventilation in the tropical rainforest climate, and PCM 28 applied together with mechanical ventilation could be used as the optimum combination for the whole climate zone.
Keywords: Af climate zone; phase change materials; daily peak temperature drop; total temperature drop; natural ventilation; mechanical ventilation (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (2)
Downloads: (external link)
https://www.mdpi.com/1996-1073/14/9/2699/pdf (application/pdf)
https://www.mdpi.com/1996-1073/14/9/2699/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:14:y:2021:i:9:p:2699-:d:550770
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().