Development of PMU-Based Transient Stability Detection Methods Using CNN-LSTM Considering Time Series Data Measurement

Izzuddin Fathin Azhar, Lesnanto Multa Putranto () and Roni Irnawan
Additional contact information
Izzuddin Fathin Azhar: Department of Electrical and Information Engineering, Engineering Faculty, Universitas Gadjah Mada, Jl. Grafika No 2 Engineering Faculty Complex, Yogyakarta 55281, Indonesia
Lesnanto Multa Putranto: Department of Electrical and Information Engineering, Engineering Faculty, Universitas Gadjah Mada, Jl. Grafika No 2 Engineering Faculty Complex, Yogyakarta 55281, Indonesia
Roni Irnawan: Department of Electrical and Information Engineering, Engineering Faculty, Universitas Gadjah Mada, Jl. Grafika No 2 Engineering Faculty Complex, Yogyakarta 55281, Indonesia

Energies, 2022, vol. 15, issue 21, 1-20

Abstract: The development of electric power systems has become more complex. Consequently, electric power systems are operating closer to their limits and are more susceptible to instability when a disturbance occurs. Transient stability problems are especially prevalent. In addition, the identification of transient stability is difficult to achieve in real time using the current measurement data. This research focuses on developing a convolutional neural network—long short-term memory (CNN-LSTM) model using historical data events to detect transient stability considering time-series measurement data. The model was developed by considering noise, delay, and loss in measurement data, line outage and variable renewable energy (VRE) integration scenarios. The model requires PMU measurements to provide high sampling rate time-series information. In addition, the effects of different numbers of PMUs were also simulated. The CNN-LSTM method was trained using a synthetic dataset produced using the DigSILENT PowerFactory simulation to represent the PMU measurement data. The IEEE 39 bus test system was used to simulate the model under different loading conditions. On the basis of the research results, the proposed CNN-LSTM model is able to detect stable and unstable conditions of transient stability only from the magnitude and angle of the bus voltage, without considering system parameter information on the network. The accuracy of transient stability detection reached above 99% in all scenarios. The CNN-LSTM method also required less computation time compared to CNN and conventional LSTM with the average computation times of 190.4, 4001.8 and 229.8 s, respectively.

Keywords: transient stability; transient stability detection; prediction accuracy; CNN-LSTM (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/1996-1073/15/21/8241/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/21/8241/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:21:p:8241-:d:963525

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:15:y:2022:i:21:p:8241-:d:963525