Development of Ultra-High-Efficiency Medium-Capacity Chillers with Two-Stage Compression and Interstage Vapor Injection Technologies
Zhiping Zhang,
Hongye Qiu,
Dantong Li (dantongli@xjtu.edu.cn),
Zhilong He,
Ziwen Xing and
Lijian Wu
Additional contact information
Zhiping Zhang: College of Electrical Engineering, Zhejiang University, Hangzhou 310027, China
Hongye Qiu: College of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, China
Dantong Li: College of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, China
Zhilong He: College of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, China
Ziwen Xing: College of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, China
Lijian Wu: College of Electrical Engineering, Zhejiang University, Hangzhou 310027, China
Energies, 2022, vol. 15, issue 24, 1-19
Abstract:
Chillers are widely used in commercial buildings for air conditioning, and their energy consumption is the main contribution to the building’s carbon emissions. Currently, the COPs of small- and medium-capacity screw chillers are still generally lower than 6.5, whereas large-capacity commercial centrifugal chillers have achieved an ultra-high energy-efficiency level of COP ≥ 7.0. To achieve an ultra-high energy efficiency of COP ≥ 6.5 in medium-capacity chillers, the authors developed a 200 RT screw chiller by adopting the technologies of two-stage compression and interstage vapor injection. The whole development process, including the design, simulation, analysis, and experiment, is presented in this paper. It was found that the two-stage compression technology could effectively boost the performance of the chiller’s compressor to a maximum volumetric and adiabatic efficiency of 99% and 80%, respectively. With the interstage vapor injection technology, the chiller’s cooling capacity and COP were increased by more than 11% and 8%, respectively. When the use of these two technologies was combined, the maximum COP of the chiller reached 7.17. Additionally, under these working conditions, the COP and integrated part-load value (IPLV) were 6.74 and 10.04, respectively. In all, the combination use of vapor injection and two-stage compression technologies shows great potential to improve the performance of chillers. The work and conclusions described here might provide an effective reference for the future development of high-efficiency small- and medium-capacity screw chillers.
Keywords: two-stage compression; vapor injection; screw compressor; medium-capacity chiller (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: Add references at CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/15/24/9562/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/24/9562/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:24:p:9562-:d:1005765
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager (indexing@mdpi.com).