EconPapers    
Economics at your fingertips  
 

Advanced Exergy Analysis of Ultra-Low GWP Reversible Heat Pumps for Residential Applications

Volodymyr Voloshchuk, Paride Gullo (parigul@sdu.dk) and Eugene Nikiforovich
Additional contact information
Volodymyr Voloshchuk: Department of Energy Processes Automation, National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute”, 03056 Kyiv, Ukraine
Paride Gullo: Department of Mechanical and Electrical Engineering, University of Southern Denmark (SDU), 6400 Sønderborg, Denmark
Eugene Nikiforovich: Department of Nuclear Energy, National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute”, 03056 Kyiv, Ukraine

Energies, 2023, vol. 16, issue 2, 1-17

Abstract: Exergy-based methods provide engineers with the best information with respect to options for improving the overall thermodynamic efficiency of an energy conversion system. This paper presents the results of an advanced exergy analysis of an air-to-water reversible heat pump whose performance was analyzed with respect to different working fluids. Environmentally deleterious refrigerants, i.e., R410A and R134a (baselines), and their eco-friendly replacements (R290, R152a, R1234ze(E), and R1234yf) were selected. The evaluations were conducted under the same operating conditions (i.e., with the same cooling and heating demands and outdoor temperatures). Based on conventional exergy analysis, it was determined that different priorities should be given for the thermodynamic improvement of the components according to which heating and cooling modes of the system are in use. Therefore, integrated parameters, i.e., the annual values of exergy destruction, were applied for further analysis. The results obtained showed that the heat pump using R410A provided the largest degree of annual exergy destruction estimated on the basis of conventional exergy analysis (5913 kWh), whereas the heat pump using R290 offered the lowest one (4522 kWh). The annual exergy destruction of the R410A cycle with only unavoidable irreversibilities could be decreased by 50%. In this case, compared to R410A and R134a, R152a and R290 provided lower values of the total annual unavoidable aspects of exergy destruction. Considering technological limitations, when removing all the avoidable irreversibilities within the air exchanger, the largest decrease in the total exergy destruction within the system could be reached. The results obtained from the analysis of the removable irreversibilities showed that the mutual interactions between the compressor, evaporator, and condenser were weak. Finally, it was concluded that, from a thermodynamic point of view, the adoption of R152a and R290 in reversible air-to-water heat pumps as replacements for R410A and R134a is advisable.

Keywords: eco-friendly refrigerants; exergetic analysis; exergy destruction; propane; sustainable cooling and heating (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: Add references at CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/16/2/703/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/2/703/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:2:p:703-:d:1028078

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager (indexing@mdpi.com).

 
Page updated 2024-12-28