Modeling, Energy Performance and Economic Analysis of Rooftop Solar Photovoltaic System for Net Energy Metering Scheme in Malaysia
Muhammad Firdaus Mohd Zublie,
Md. Hasanuzzaman () and
Nasrudin Abd Rahim
Additional contact information
Muhammad Firdaus Mohd Zublie: Higher Institution Centre of Excellence (HICoE), UM Power Energy Dedicated Advanced Centre (UMPEDAC), Level 4, Wisma R&D UM, Jalan Pantai Baharu, Kuala Lumpur 59990, Malaysia
Md. Hasanuzzaman: Higher Institution Centre of Excellence (HICoE), UM Power Energy Dedicated Advanced Centre (UMPEDAC), Level 4, Wisma R&D UM, Jalan Pantai Baharu, Kuala Lumpur 59990, Malaysia
Nasrudin Abd Rahim: Higher Institution Centre of Excellence (HICoE), UM Power Energy Dedicated Advanced Centre (UMPEDAC), Level 4, Wisma R&D UM, Jalan Pantai Baharu, Kuala Lumpur 59990, Malaysia
Energies, 2023, vol. 16, issue 2, 1-18
Abstract:
Energy is one of the essential inputs for modernization and social development. Energy demand is increasing, and the primary energy source is fossil fuels, which negatively impact the environment. Energy saving and renewables are the potential solutions which could minimize environmental impact. This paper investigates the energy-saving and solar photovoltaic energy potential of an educational institution, Politeknik Sultan Azlan Shah (PSAS), Malaysia. The feasibility analysis was conducted by assuming that PSAS joined the Net Energy Metering (NEM 3.0) program, where PSAS, as a NEM consumer, has a tripartite supply agreement with renewable energy (SARE) with a distribution licensee known as Tenaga National Berhad (TNB). This paper focuses on zero capital expenditure (CAPEX) saving through a 20-year contract. This paper proposes a rooftop solar photovoltaic diagram using a NEM meter installed in the ring distribution system at PSAS. The estimated savings to be obtained by PSAS in the 20 years that the contract is in force are calculated based on the assumption that the installed solar system has a capacity of 688 kW. The maximum value of power generated by the system for a year is 990,720 kWh. The feasibility analysis found that the cumulative net savings estimate for PSAS based on the overall calculation for 21 years of solar use is RM 3,534,250. Meanwhile, the cumulative assessment of carbon emission reduction obtained in the same period is 14,559,760 kg CO 2 or 14,559.76 tons of CO 2 , which would save 363,994 mature trees from being cut down.
Keywords: feasibility analysis; rooftop solar photovoltaic; zero capital expenditure; net energy metering; educational institution (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (2)
Downloads: (external link)
https://www.mdpi.com/1996-1073/16/2/723/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/2/723/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:2:p:723-:d:1028507
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().