Advanced Method of Variable Refrigerant Flow (VRF) Systems Designing to Forecast Onsite Operation—Part 2: Phenomenological Simulation to Recoup Refrigeration Energy
Mykola Radchenko,
Andrii Radchenko,
Eugeniy Trushliakov,
Hanna Koshlak () and
Roman Radchenko
Additional contact information
Mykola Radchenko: Machinebuilding Institute, Admiral Makarov National University of Shipbuilding, Heroes of Ukraine Avenue 9, 54025 Mykolayiv, Ukraine
Andrii Radchenko: Machinebuilding Institute, Admiral Makarov National University of Shipbuilding, Heroes of Ukraine Avenue 9, 54025 Mykolayiv, Ukraine
Eugeniy Trushliakov: Department of Air Conditioning and Refrigeration, Admiral Makarov National University of Shipbuilding, Heroes of Ukraine Avenue 9, 54025 Mykolayiv, Ukraine
Hanna Koshlak: Department of Sanitary Engineering, Kielce University of Technology, Al. Tysiąclecia Państwa Polskiego 7, 25-314 Kielce, Poland
Roman Radchenko: Machinebuilding Institute, Admiral Makarov National University of Shipbuilding, Heroes of Ukraine Avenue 9, 54025 Mykolayiv, Ukraine
Energies, 2023, vol. 16, issue 4, 1-17
Abstract:
This paper focuses on the application of speed-regulated compressors (SRCs) to cover changeable heat loads with high efficiency in conventional air conditioning systems (ACS) as well as in the more advanced variable refrigerant flow (VRF)-type outdoor and indoor ACS. In reality, an SRC is an oversized compressor, although it can operate efficiently at part loads. The higher the level of regulated loads (LRL) of the SRC, the more the compressor is oversized. It is preferable to reduce the size of the SRC by covering the peak loads and recouping the excessive refrigeration energy reserved at decreased actual loads within the range of regulated loads. Therefore, the range of changeable loads is chosen as the object to be narrowed by using the reserved refrigeration capacity. Thus, the general fundamental approach of dividing the overall heat load range of the ACS into the ranges with changeable and unchangeable loads, as previously developed by the authors, is applied for the range of primary changeable loads. Due to this innovative step, the principle of two-stage outdoor air conditioning according to changeable and unchangeable loads, also proposed by the authors, has been extended over the range of primary changeable loads to reduce the level of refrigeration capacity regulation and SRC size. To realize this, part of the changeable load range is offset by the reserved refrigeration capacity, leading to a reduction in the changeable load range and the SRC size by approximately 20% for temperate climatic conditions.
Keywords: air conditioning system; load range; refrigeration capacity excess; threshold temperature; level of loading (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/16/4/1922/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/4/1922/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:4:p:1922-:d:1069200
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().