Analysis of the Impact of Water Flow Rate on the Temperature Variability in a Closed Room during the Extinguishing of A-Group Fire Using a Hybrid Water Mist Suppression System
Jerzy Gałaj,
Norbert Tuśnio,
Paweł Wolny and
Tomasz Drzymała
Additional contact information
Jerzy Gałaj: Institute of Safety Engineering, The Main School of Fire Service, Słowackiego Str. 52/54, 01-629 Warsaw, Poland
Norbert Tuśnio: Faculty of Safety Engineering and Civil Protection, The Main School of Fire Service, Słowackiego Str. 52/54, 01-629 Warsaw, Poland
Paweł Wolny: Faculty of Process Engineering and Environmental Protection, Lodz University of Technology, Wólczańska 213, 90-001 Łódź, Poland
Tomasz Drzymała: Faculty of Safety Engineering and Civil Protection, The Main School of Fire Service, Słowackiego Str. 52/54, 01-629 Warsaw, Poland
Sustainability, 2020, vol. 12, issue 20, 1-14
Abstract:
The advantage of hybrid fire suppression systems is that they combine the advantages of both water mist and clean agent systems. Currently, this innovative technology is increasingly used in fixed firefighting systems. Available literature both in Polish and around the world describes this issue in a fragmentary way. Extinguishing system tests were carried out at the Main School of Fire Service in Warsaw. The impact of water mist flow rate on the temperature variability in a closed room during the extinguishing of group A fires using a hybrid water mist system was analyzed. Four different flow rates 0.5, 1.0, 1.5 and 3.0 dm 3 /min were applied. The temperature variability of selected points of a closed test chamber during extinguishing process are presented. The extinguishing efficiency, taking into account extinguishing time, average speed of temperature drop and other parameters, was estimated on the basis of proposed original criterion. The results obtained showed that water flow rate has a significant impact on temperature variability and included the determination of optimal water flow rate at which the extinguishing efficiency is the highest. The conducted research proved that the hybrid system is more effective than classic mist and gas systems when extinguishing group A fires.
Keywords: hybrid water mist system; internal fire; fire extinguishing; water mist fire suppression system; fire environment; fixed extinguishing device; group A fire (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2020
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/2071-1050/12/20/8700/pdf (application/pdf)
https://www.mdpi.com/2071-1050/12/20/8700/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:12:y:2020:i:20:p:8700-:d:431898
Access Statistics for this article
Sustainability is currently edited by Ms. Alexandra Wu
More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().