EconPapers    
Economics at your fingertips  
 

Thermal Comfort Improvement for Atrium Building with Double-Skin Skylight in the Mediterranean Climate

Refaa Sokkar and Halil Z. Alibaba
Additional contact information
Refaa Sokkar: Department of Architecture, Faculty of Architecture, Eastern Mediterranean University, via Mersin 10, 99628 Famagusta, North Cyprus, Turkey
Halil Z. Alibaba: Department of Architecture, Faculty of Architecture, Eastern Mediterranean University, via Mersin 10, 99628 Famagusta, North Cyprus, Turkey

Sustainability, 2020, vol. 12, issue 6, 1-26

Abstract: Atria are added to buildings for their aesthetical, environmental, and economic benefits; the appropriate atrium design can enhance an atrium’s thermal performance and the adjacent spaces’ temperatures. However, inappropriate design decisions cause thermal discomfort and consequently, higher energy consumption. Since the Mediterranean climate has diverse climatic conditions around the year, a central atrium with a top-lit skylight is recommended, but during the summer period it can cause overheating, and the insertion of shading elements shrinks the lighting performance: thus, the atrium skylight design is supposed to improve thermal comfort without affecting the lighting level. This study investigated the improvement of thermal performance in the atrium building by the implementation of a double-skin skylight (DSS) to enhance the atrium thermal performance without shading. The research conducted computer simulations with Environmental Design Solutions (EDSL) Tas software sequentially. The study prepared various design strategies, and different proposals were tested and compared in terms of indoor temperatures, with reference to American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE-55). The implementation of DSS achieved an average of 77% comfort in working hours around the year with different opening percentages according to the outdoor conditions. Moreover, results show that changing the DSS glazing materials did not affect the thermal performance of the atrium.

Keywords: atrium; natural ventilation; thermal comfort; passive design strategy; Mediterranean climate; double skin skylight (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2020
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/2071-1050/12/6/2253/pdf (application/pdf)
https://www.mdpi.com/2071-1050/12/6/2253/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:12:y:2020:i:6:p:2253-:d:332136

Access Statistics for this article

Sustainability is currently edited by Ms. Alexandra Wu

More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jsusta:v:12:y:2020:i:6:p:2253-:d:332136