EconPapers    
Economics at your fingertips  
 

Line Overload Alleviations in Wind Energy Integrated Power Systems Using Automatic Generation Control

Kaleem Ullah, Abdul Basit (), Zahid Ullah, Rafiq Asghar, Sheraz Aslam () and Ayman Yafoz
Additional contact information
Kaleem Ullah: US-Pakistan Center for Advanced Study in Energy, University of Engineering and Technology Peshawar, Peshawar 25000, Pakistan
Abdul Basit: US-Pakistan Center for Advanced Study in Energy, University of Engineering and Technology Peshawar, Peshawar 25000, Pakistan
Zahid Ullah: Department of Electrical Engineering, University of Management and Technology Lahore, Sialkot Campus, Sialkot 51310, Pakistan
Rafiq Asghar: Faculty of Electrical & Electronics Engineering, Universiti Malaysia Pahang (UMP), Pekan 26600, Malaysia
Sheraz Aslam: Department of Electrical Engineering, Computer Engineering and Informatics, Cyprus University of Technology, Limassol 3036, Cyprus
Ayman Yafoz: Department of Information Systems, Faculty of Computing and Information Technology, King Abdulaziz University, Jeddah 21589, Saudi Arabia

Sustainability, 2022, vol. 14, issue 19, 1-19

Abstract: Modern power systems are largely based on renewable energy sources, especially wind power. However, wind power, due to its intermittent nature and associated forecasting errors, requires an additional amount of balancing power provided through the automatic generation control (AGC) system. In normal operation, AGC dispatch is based on the fixed participation factor taking into account only the economic operation of generating units. However, large-scale injection of additional reserves results in large fluctuations of line power flows, which may overload the line and subsequently reduce the system security if AGC follows the fixed participation factor’s criteria. Therefore, to prevent the transmission line overloading, a dynamic dispatch strategy is required for the AGC system considering the capacities of the transmission lines along with the economic operation of generating units. This paper proposes a real-time dynamic AGC dispatch strategy, which protects the transmission line from overloading during the power dispatch process in an active power balancing operation. The proposed method optimizes the control of the AGC dispatch order to prevent power overflows in the transmission lines, which is achieved by considering how the output change of each generating unit affects the power flow in the associated bus system. Simulations are performed in Dig SILENT software by developing a 5 machine 8 bus Pakistan’s power system model integrating thermal power plant units, gas turbines, and wind power plant systems. Results show that the proposed AGC design efficiently avoids the transmission line congestions in highly wind-integrated power along with the economic operation of generating units.

Keywords: automatic generation control; wind energy; transmission line security; dispatch strategies; Pakistan power system (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (3)

Downloads: (external link)
https://www.mdpi.com/2071-1050/14/19/11810/pdf (application/pdf)
https://www.mdpi.com/2071-1050/14/19/11810/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:14:y:2022:i:19:p:11810-:d:919551

Access Statistics for this article

Sustainability is currently edited by Ms. Alexandra Wu

More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jsusta:v:14:y:2022:i:19:p:11810-:d:919551