Thermal Performance and Optimizing of Composite Trombe Wall with Temperature-Controlled DC Fan in Winter

Yuewei Zhu, Tao Zhang, Qingsong Ma and Hiroatsu Fukuda
Additional contact information
Yuewei Zhu: Innovation Institute for Sustainable Maritime Architecture Research and Technology, Qingdao University of Technology, Qingdao 266033, China
Tao Zhang: Innovation Institute for Sustainable Maritime Architecture Research and Technology, Qingdao University of Technology, Qingdao 266033, China
Qingsong Ma: Innovation Institute for Sustainable Maritime Architecture Research and Technology, Qingdao University of Technology, Qingdao 266033, China
Hiroatsu Fukuda: Faculty of Environmental Engineering, The University of Kitakyushu, Kitakyushu 808-0135, Japan

Sustainability, 2022, vol. 14, issue 5, 1-15

Abstract: This paper discusses an improved approach to the Trombe wall: an insulated panel is installed on the inner side, and vents are installed at the top and bottom to connect the outer and inner air layer with the interior. Direct current (DC) fans are installed in the upper vents for stable control of the air circulation. The study first analyzed the thermal performance of this composite Trombe wall, for which the heat load was 27.3% less compared to the classic Trombe wall and 32.1% less compared to the case without the Trombe wall. However, its efficiency for heating the room temperature was not high without heating. Then, we optimized the ventilation efficiency, the proportion of the Trombe wall in the room, and the type of glazing. The highest heat load savings could be achieved when the ventilation openings used high ventilation with temperature-controlled fans and the Trombe wall about 3% of the house floor area. With the use of Low-e double-glazing, we were able to save nearly 41.3% of the heat load than that with the regular single-glazing. For the composite Trombe wall, after taking into account the optimization factors, the room temperature was significantly higher, and could save nearly 52.3% of energy compared to the pre-optimization period.

Keywords: Trombe wall; DC fan; simulation; heating load; THERB for Ham (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (5)

Downloads: (external link)
https://www.mdpi.com/2071-1050/14/5/3080/pdf (application/pdf)
https://www.mdpi.com/2071-1050/14/5/3080/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:14:y:2022:i:5:p:3080-:d:765442

Access Statistics for this article

Sustainability is currently edited by Ms. Alexandra Wu

More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jsusta:v:14:y:2022:i:5:p:3080-:d:765442