Temperature Distribution and Equipment Layout in a Deep Chamber: A Case Study of a Coal Mine Substation

Kaiwen Hu, Jian Zheng, Hai Wu and Qian Jia
Additional contact information
Kaiwen Hu: School of Architecture, South China University of Technology, Guangzhou 510641, China
Jian Zheng: School of Architecture, South China University of Technology, Guangzhou 510641, China
Hai Wu: Work Safety Key Lab on Prevention and Control of Gas and Roof Disasters for Southern Coal Mines, Hunan University of Science and Technology, Xiangtan 411201, China
Qian Jia: Work Safety Key Lab on Prevention and Control of Gas and Roof Disasters for Southern Coal Mines, Hunan University of Science and Technology, Xiangtan 411201, China

Sustainability, 2022, vol. 14, issue 7, 1-12

Abstract: With the gradual depletion of shallow resources, the process of resource exploitation is being transferred to greater depths. The temperature of the surrounding rock increases gradually in the process of deep mining, and the temperature of the underground substation chambers often exceeds the normal working temperature in summer. In this paper, the equipment layout and ventilation conditions of the deep substation chamber of the Jiangxi Qujiang Mining Company were selected as the research subjects, and numerical simulation software was used to study the temperature distribution within the chamber under different conditions by changing the combinations of the wind velocity and air temperature of the inlet air of the chamber. The study showed that, under the conditions of the current equipment layout and air door size, the equipment temperature was prone to being too high in the summer. Therefore, the layout of the equipment was optimized based on the simulation results. The transformer equipment was changed from the original serial mode to the juxtaposed mode, and the size of the air door was increased, which effectively reduced the disturbance of the air flow and the length of the air flow path in the chamber. This meant that the high temperature area of the chamber was at the end of the chamber, which efficiently reduced the area of the high temperature zone and ensured that the equipment was in a lower temperature environment. This method can be used as a reference for temperature distribution, layout, and temperature control measures within buildings.

Keywords: deep chamber; temperature distribution; juxtaposed; cooling measures; equipment layout (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/2071-1050/14/7/3852/pdf (application/pdf)
https://www.mdpi.com/2071-1050/14/7/3852/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:14:y:2022:i:7:p:3852-:d:779120

Access Statistics for this article

Sustainability is currently edited by Ms. Alexandra Wu

More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jsusta:v:14:y:2022:i:7:p:3852-:d:779120