EconPapers    
Economics at your fingertips  
 

Long-Term Field Observation of the Power Generation and System Temperature of a Roof-Integrated Photovoltaic System in South Korea

Muhammad Hanif Ainun Azhar, Salh Alhammadi, Seokjin Jang, Jitaek Kim, Jungtaek Kim and Woo Kyoung Kim ()
Additional contact information
Muhammad Hanif Ainun Azhar: School of Chemical Engineering, Yeungnam University, 280 Daehak-ro, Gyeongsan 38541, Gyeongbuk, Republic of Korea
Salh Alhammadi: School of Chemical Engineering, Yeungnam University, 280 Daehak-ro, Gyeongsan 38541, Gyeongbuk, Republic of Korea
Seokjin Jang: School of Chemical Engineering, Yeungnam University, 280 Daehak-ro, Gyeongsan 38541, Gyeongbuk, Republic of Korea
Jitaek Kim: Roser Roofing System, 43, Nae-Ri-19, Ammyang-myeon, Gyeongsan 38539, Gyeongbuk, Republic of Korea
Jungtaek Kim: Roser Roofing System, 43, Nae-Ri-19, Ammyang-myeon, Gyeongsan 38539, Gyeongbuk, Republic of Korea
Woo Kyoung Kim: School of Chemical Engineering, Yeungnam University, 280 Daehak-ro, Gyeongsan 38541, Gyeongbuk, Republic of Korea

Sustainability, 2023, vol. 15, issue 12, 1-15

Abstract: A miniature house roof-integrated photovoltaic (PV) system in South Korea was monitored for 2.5 years. System performance was evaluated through power generation, solar irradiance, and system temperature. The comparison of each month’s power generation and solar irradiance revealed a parallel correlation over the entire observation period. The internal module temperature was almost always higher than the roof rear and module rear temperatures by 1–2 and 1–5 °C, respectively, while the temperature behind the PV modules was the lowest among the three temperatures, showing that the installation of PV modules as a roofing system does not affect the temperature of the roofing system. The system temperatures affected the power conversion efficiency; a maximum of 11.42% was achieved when the system temperatures were the lowest, and a minimum of 5.24% was achieved when the system temperatures were the highest. Hence, half of the anticipated generated power was lost due to the temperature fluctuation. Overall, installing PV modules as an entire roofing system is possible with this configuration due to the minimum effect on the roof temperature. However, PV system temperature control is essential for maintaining the power generation performance of the PV modules.

Keywords: building-integrated photovoltaics; roof-integrated photovoltaics; photovoltaic module temperature; building-integrated photovoltaic system temperature (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/2071-1050/15/12/9493/pdf (application/pdf)
https://www.mdpi.com/2071-1050/15/12/9493/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:15:y:2023:i:12:p:9493-:d:1170078

Access Statistics for this article

Sustainability is currently edited by Ms. Alexandra Wu

More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jsusta:v:15:y:2023:i:12:p:9493-:d:1170078