Comprehensive Research on the Near-Zero Energy Consumption of an Office Building in Hefei Based on a Photovoltaic Curtain Wall
Haitao Wang (),
Fanghao Wu,
Ning Lu and
Jianfeng Zhai
Additional contact information
Haitao Wang: School of Environment and Energy Engineering, Anhui Jianzhu University, Hefei 230601, China
Fanghao Wu: School of Environment and Energy Engineering, Anhui Jianzhu University, Hefei 230601, China
Ning Lu: School of Environment and Energy Engineering, Anhui Jianzhu University, Hefei 230601, China
Jianfeng Zhai: School of Environment and Energy Engineering, Anhui Jianzhu University, Hefei 230601, China
Sustainability, 2023, vol. 15, issue 15, 1-17
Abstract:
The near-zero energy design of a building is linked to the regional climate in which the building is located. On the basis of studying the cavity size and ground height of a photovoltaic curtain wall, the power generation efficiency of the photovoltaic curtain wall under different ground heights is compared in this paper. According to the “Technical Standard for Near-Zero Energy Buildings”, the personnel and lighting of a 12-m office building in Hefei were parametrically arranged and three design schemes for near-zero energy buildings were proposed. The energy consumption of the benchmark building and the design energy consumption of each scheme were calculated by using the energy consumption simulation software Design Builder V 7.0.0.096; the feasibility of realizing the near-zero energy consumption building by using each scheme was checked. The results show that when the cavity width of the photovoltaic curtain wall of the office building is 70 mm, the cavity heat transfer coefficient is the lowest and the heat insulation of the building is the best. When the height from the ground is 0.7 m, the power generation efficiency of the photovoltaic curtain wall reaches a maximum of 18.39% and the south façade of the building is more suitable for the layout and installation of the photovoltaic curtain wall. The single-façade photovoltaic curtain wall should be combined with a high-efficiency air conditioning system and lighting system; the installation of a photovoltaic rooftop at the same time can meet the design requirements of near-zero energy buildings in hot-summer and cold-winter areas. This paper provides some guidance for exploring the design of near-zero energy office buildings, which is of practical significance.
Keywords: photovoltaic curtain wall; cavity size; height from ground; near-zero energy buildings (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/2071-1050/15/15/11701/pdf (application/pdf)
https://www.mdpi.com/2071-1050/15/15/11701/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:15:y:2023:i:15:p:11701-:d:1205617
Access Statistics for this article
Sustainability is currently edited by Ms. Alexandra Wu
More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().