The Effect of Lowering Indoor Air Temperature on the Reduction in Energy Consumption and CO 2 Emission in Multifamily Buildings in Poland
Paweł Szałański,
Piotr Kowalski (),
Wojciech Cepiński and
Piotr Kęskiewicz
Additional contact information
Paweł Szałański: Department of Air Conditioning, Heating, Gas Engineering, and Air Protection, Faculty of Environmental Engineering, Wroclaw University of Science and Technology, 50-370 Wroclaw, Poland
Piotr Kowalski: Department of Air Conditioning, Heating, Gas Engineering, and Air Protection, Faculty of Environmental Engineering, Wroclaw University of Science and Technology, 50-370 Wroclaw, Poland
Wojciech Cepiński: Department of Air Conditioning, Heating, Gas Engineering, and Air Protection, Faculty of Environmental Engineering, Wroclaw University of Science and Technology, 50-370 Wroclaw, Poland
Piotr Kęskiewicz: Department of Air Conditioning, Heating, Gas Engineering, and Air Protection, Faculty of Environmental Engineering, Wroclaw University of Science and Technology, 50-370 Wroclaw, Poland
Sustainability, 2023, vol. 15, issue 15, 1-19
Abstract:
This article analyzes the possibility of reducing the energy consumption from building heating as a result of lowering the indoor air temperature, which is recommended as a response to the energy crisis. Various values of the set-point temperature (16–22 °C), as well as different scenarios for their changes, were assumed for analysis. Changes in clothing that were determined to maintain the same level of thermal comfort after a temperature change were determined. The associated reduction in CO 2 emissions emitted into the atmosphere was determined. The effect of reducing CO 2 emissions was studied depending on the type of heating source. Simulation calculations were carried out for an exemplary multifamily building. The effect of different building insulations required in Poland over the years 1964–2022 was considered. Analyses were performed for the climatic conditions of cities located in different climatic zones of Poland: Koszalin, Wroclaw, Warsaw, Bialystok, Suwalki. Depending on the scenario, the insulation standard of the building, and the variant of location, the energy reduction achieved ranges from 6.6%/K to 13.2%/K. Taking into account the type of heating source, the reduction in CO 2 emissions is from 0.7 to 7.5 kgCO 2 /(K·m 2 ). The reduction in temperature by 1 or 2 K can be compensated for by wearing an additional sleeveless vest (0.12 clo) or sweater (0.28 clo).
Keywords: energy crisis; energy savings; reduction of emission; thermal comfort (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/2071-1050/15/15/12097/pdf (application/pdf)
https://www.mdpi.com/2071-1050/15/15/12097/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:15:y:2023:i:15:p:12097-:d:1212381
Access Statistics for this article
Sustainability is currently edited by Ms. Alexandra Wu
More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().