Analysis of the Influence of Office Building Operating Characteristics on Carbon Emissions in Cold Regions

Wenfei Wang, Ning Kang, Fang He and Xiaoping Li ()
Additional contact information
Wenfei Wang: China Academy of Building Research, Beijing 100013, China
Ning Kang: China Academy of Building Research Tianjin Institute, Tianjin 300380, China
Fang He: China Academy of Building Research Tianjin Institute, Tianjin 300380, China
Xiaoping Li: China Academy of Building Research Tianjin Institute, Tianjin 300380, China

Sustainability, 2023, vol. 15, issue 18, 1-15

Abstract: Reducing buildings’ operational carbon dioxide emissions has become a crucial element in China’s efforts to achieve carbon peak and carbon neutrality targets. This study focus on the influence of office building operating characteristics on carbon emissions in cold regions. By utilizing DesignBuilder v7.0.0.096 to conduct numerical simulations of 10 different operating conditions for heating, ventilation and air-conditioning (HVAC) and lighting systems, this study solves the problems in the past of poor comfort and high energy consumption with manual management and achieves a win-win situation for health and environmental protection. The study shows that by implementing a mixed mode of mechanical ventilation and natural ventilation based on outdoor climate conditions and design requirements, unsatisfied hours can be reduced by 202 h compared to the traditional air condition heating operation mode for both winter and summer seasons. Furthermore, compared to a year-round HVAC operation mode, the air-conditioning energy consumption can be reduced by 19%, resulting in a carbon emissions reduction of 1.45 kg CO 2 /(m 2 ·a). Additionally, for every 2 °C increase in the outdoor temperature, the cooling energy consumption decreases by 2–5%. In terms of lighting, the intelligent lighting mode can reduce energy consumption by 31.04%, leading to a carbon emissions reduction of 3.04 kg CO 2 /(m 2 ·a). The coupling operation characteristics of mixed mode, intelligent lighting, and energy-saving lamps can achieve a maximum saving of 83.46 MWh of electricity and approximately CNY 72,000 every year, with a static payback period of approximately 2.7 years. This operational strategy, which fully considers the utilization of natural ventilation and daylighting in conjunction with traditional design approaches, improves indoor air quality and ventilation conditions, while also maximizing the energy-saving and carbon reduction potential. The study results provide valuable design and operational guidance for new and existing office buildings in cold regions, to effectively reduce carbon emissions, while offering significant investment returns.

Keywords: building energy; HVAC scheduling; building operation; energy efficiency measures (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/2071-1050/15/18/13342/pdf (application/pdf)
https://www.mdpi.com/2071-1050/15/18/13342/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:15:y:2023:i:18:p:13342-:d:1233850

Access Statistics for this article

Sustainability is currently edited by Ms. Alexandra Wu

More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jsusta:v:15:y:2023:i:18:p:13342-:d:1233850