Maintenance and Energy Optimization of Lighting Systems for the Improvement of Historic Buildings: A Case Study
Ferdinando Salata,
Iacopo Golasi,
Giacomo Falanga,
Marco Allegri,
Emanuele De Lieto Vollaro,
Fabio Nardecchia,
Francesca Pagliaro,
Franco Gugliermetti and
Andrea De Lieto Vollaro
Additional contact information
Ferdinando Salata: DIAEE—Area Fisica Tecnica, Università degli Studi di Roma "Sapienza", Via Eudossiana, Rome 18 00184, Italy
Iacopo Golasi: DIAEE—Area Fisica Tecnica, Università degli Studi di Roma "Sapienza", Via Eudossiana, Rome 18 00184, Italy
Giacomo Falanga: DIAEE—Area Fisica Tecnica, Università degli Studi di Roma "Sapienza", Via Eudossiana, Rome 18 00184, Italy
Marco Allegri: DIAEE—Area Fisica Tecnica, Università degli Studi di Roma "Sapienza", Via Eudossiana, Rome 18 00184, Italy
Emanuele De Lieto Vollaro: DIMI—Università degli Studi "Roma TRE", Via Vito Volterra, Rome 62 00146, Italy
Fabio Nardecchia: DIAEE—Area Fisica Tecnica, Università degli Studi di Roma "Sapienza", Via Eudossiana, Rome 18 00184, Italy
Francesca Pagliaro: DIAEE—Area Fisica Tecnica, Università degli Studi di Roma "Sapienza", Via Eudossiana, Rome 18 00184, Italy
Franco Gugliermetti: DIAEE—Area Fisica Tecnica, Università degli Studi di Roma "Sapienza", Via Eudossiana, Rome 18 00184, Italy
Andrea De Lieto Vollaro: DIAEE—Area Fisica Tecnica, Università degli Studi di Roma "Sapienza", Via Eudossiana, Rome 18 00184, Italy
Sustainability, 2015, vol. 7, issue 8, 1-19
Abstract:
Proper lighting is vital to improve, from an artistic point of view, the surface expanse and decorative detailing of architectural heritage buildings considered valuable. When properly lit, monumental buildings can become to onlookers an essential part of the city. Nowadays, for design planners dealing with the improvement of buildings, whose architectural design should be valorized, the real challenge is to combine the lighting artistic requirements with scrupulous economic management in order to limit the energy demand and to respect the environment. For these reasons, this case study examines the lighting of the monumental façade and the cloister of St. Peter in Chains situated in the Faculty of Engineering of Sapienza University of Rome. The present lighting installation, characterized by metal halides, compact fluorescent and halogen lamps, is compared with an alternative scenario presenting LED lamps and scenographic lighting of the monumental façade. Such comparison is based on the evaluation of the lighting levels for different visual tasks and on energy and maintenance issues; the first analysis was performed through the software DIALux Evo 4.0, whereas the second was performed using ecoCALC. This study leads to the conclusion that the lighting levels of the solution presenting LED lamps are better than those of the present solution, and they comply with current standards. Finally, the higher costs of LED lamp installations and the scenographic lighting of the monumental façade are balanced by lower maintenance costs, with a payback period of seven years.
Keywords: lighting simulations; LED; historic buildings; maintenance; economic analysis (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2015
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (10)
Downloads: (external link)
https://www.mdpi.com/2071-1050/7/8/10770/pdf (application/pdf)
https://www.mdpi.com/2071-1050/7/8/10770/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:7:y:2015:i:8:p:10770-10788:d:53877
Access Statistics for this article
Sustainability is currently edited by Ms. Alexandra Wu
More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().