EconPapers    
Economics at your fingertips  
 

Study on Fault Current Characteristics and Current Limiting Method of Plug-In Devices in VSC-DC Distribution System

Yuqun Gao, Yongxia Han, Jinghan Zhang, Fanglei Xiao, Yuming Zhao and Licheng Li
Additional contact information
Yuqun Gao: School of Electric Power, South China University of Technology, Guangzhou 510640, China
Yongxia Han: School of Electric Power, South China University of Technology, Guangzhou 510640, China
Jinghan Zhang: School of Electric Power, South China University of Technology, Guangzhou 510640, China
Fanglei Xiao: School of Electric Power, South China University of Technology, Guangzhou 510640, China
Yuming Zhao: Shenzhen Power Supply Corporation, China Southern Power Grid, Shenzhen 518048, China
Licheng Li: School of Electric Power, South China University of Technology, Guangzhou 510640, China

Energies, 2019, vol. 12, issue 16, 1-16

Abstract: The DC (Direct Current) distribution system based on the voltage source converter (VSC-DC) has become a research hotspot due to its various advantages. There are many plug-in devices in the VSC-DC distribution system, which may be damaged by the fault current. Therefore, studying the fault current characteristics and current limiting method is one of the key methods to ensure the safe and stable operation of the VSC-DC distribution system. Based on theoretical analysis and simulation calculations, this paper studies the causes, influencing factors, and current limiting methods of the fault current when the pole-to-pole fault occurs at the line side of plug-in devices in a ±10 kV VSC-DC distribution system. Firstly, based on the system topology, the decisive fault condition of fault current and the design principle of current limiting reactor value are analyzed. Secondly, the theoretical calculation methods of fault current and current limiting reactor value which satisfies the breaking capacity of DC circuit breaker are proposed. Finally, the accuracy of theoretical calculation methods is verified by simulation in PSCAD/EMTDC (Power Systems Computer Aided Design/Electromagnetic Transients including DC). The research results could provide the theoretical calculation methods of the fault current and the current limiting reactor value of plug-in devices in the ±10 kV VSC-DC distribution system.

Keywords: current limiting reactor; DC circuit breaker; fault current characteristics; plug-in devices; VSC-DC distribution system (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2019
References: View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/1996-1073/12/16/3159/pdf (application/pdf)
https://www.mdpi.com/1996-1073/12/16/3159/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:12:y:2019:i:16:p:3159-:d:258370

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:12:y:2019:i:16:p:3159-:d:258370