EconPapers    
Economics at your fingertips  
 

Assessing the Energy, Indoor Air Quality, and Moisture Performance for a Three-Story Building Using an Integrated Model, Part Three: Development of Integrated Model and Applications

Seyedmohammadreza Heibati, Wahid Maref and Hamed H. Saber
Additional contact information
Seyedmohammadreza Heibati: Department of Construction Engineering, École de Technologie Supérieure (ÉTS), University of Québec, Montréal, QC H3C 1K3, Canada
Wahid Maref: Department of Construction Engineering, École de Technologie Supérieure (ÉTS), University of Québec, Montréal, QC H3C 1K3, Canada
Hamed H. Saber: Prince Saud bin Thuniyan Research Center, Mechanical Engineering Department, Jubail University College, Al Jubail 35716, Saudi Arabia

Energies, 2021, vol. 14, issue 18, 1-31

Abstract: The overall building performance depends mainly on the energy performance, indoor air quality, and moisture performance. In order to accurately calculate the building performance, the development of a model with the ability to integrate all three performances is required. In this research, a combination of three models namely EnergyPlus for energy, CONTAM for indoor air quality, and WUFI for moisture transport are used to develop an integrated model. The mechanism of this combination is based on the exchange of temperatures, airflows, and heating-cooling flows control variables between all three sub-models. By using the paired sample t -test, an integrated model is verified and its accuracy is validated. The accuracy of the integrated model is verified by the paired sample t -test. In order to analyze the accuracy of the integrated model in comparison with single models, four scenarios of airtight fan off, airtight fan on, leaky fan off, and leaky fan on are defined for a three-story-house subjected to three different climate cities of Montreal, Vancouver, and Miami. Percentage differences of simulated measures with the ASHRAE Standard are considered as the performance criteria. The simulated results by single and integrated models are compared and analyzed. Finally, the scenarios with the high performances are evaluated in terms of energy efficiency, indoor air quality, and moisture for Montreal, Vancouver, and Miami. Overall, it can be concluded that an integrated model should be developed.

Keywords: integrated model; EnergyPlus; CONTAM; WUFI; energy performance; indoor air quality; moisture performance (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (4)

Downloads: (external link)
https://www.mdpi.com/1996-1073/14/18/5648/pdf (application/pdf)
https://www.mdpi.com/1996-1073/14/18/5648/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:14:y:2021:i:18:p:5648-:d:631431

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:14:y:2021:i:18:p:5648-:d:631431