EconPapers    
Economics at your fingertips  
 

Extended Equal Area Criterion Revisited: A Direct Method for Fast Transient Stability Analysis

Alireza Bahmanyar, Damien Ernst, Yves Vanaubel, Quentin Gemine, Camille Pache and Patrick Panciatici
Additional contact information
Alireza Bahmanyar: Department of Electrical Engineering and Computer Science Montefiore Institute, University of Liège, 4000 Liège, Belgium
Damien Ernst: Department of Electrical Engineering and Computer Science Montefiore Institute, University of Liège, 4000 Liège, Belgium
Yves Vanaubel: Intelligent Systems Solutions, Haulogy, 4120 Neupré, Belgium
Quentin Gemine: Intelligent Systems Solutions, Haulogy, 4120 Neupré, Belgium
Camille Pache: French Transmission System Operator Réseau de Transport d’Electricité (RTE), 7C Place du Dome, 92800 Puteaux, France
Patrick Panciatici: French Transmission System Operator Réseau de Transport d’Electricité (RTE), 7C Place du Dome, 92800 Puteaux, France

Energies, 2021, vol. 14, issue 21, 1-48

Abstract: For transient stability analysis of a multi-machine power system, the Extended Equal Area Criterion (EEAC) method applies the classic Equal Area Criterion (EAC) concept to an approximate One Machine Infinite Bus (OMIB) equivalent of the system to find the critical clearing angle. The system-critical clearing time can then be obtained by numerical integration of OMIB equations. The EEAC method was proposed in the 1980s and 1990s as a substitute for time-domain simulation for Transmission System Operators (TSOs) to provide fast, transient stability analysis with the limited computational power available those days. To ensure the secure operation of the power system, TSOs have to identify and prevent potential critical scenarios through offline analyses of a few dangerous ones. These days, due to increased uncertainties in electrical power systems, the number of these critical scenarios is increasing, substantially, calling for fast, transient stability analysis techniques once more. Among them, the EEAC is a unique approach that provides not only valuable information, but also a graphical representation of system dynamics. This paper revisits the EEAC but from a modern, functional point of view. First, the definition of the OMIB model of a multi-machine power system is redrawn in its general form. To achieve fast, transient stability analysis, EEAC relies on approximate models of the true OMIB model. These approximations are clarified, and the EAC concept is redefined with a general definition for instability, and its conditions. Based on the defined conditions and definitions, functions are developed for each EEAC building block, which are later put out together to provide a full-resolution, functional scheme. This functional scheme not only covers the previous literature on the subject, but also allows to introduce several possible new EEAC approaches and provides a detailed description of their implementation procedure. A number of approaches are applied to the French EHV network, and the approximations are examined.

Keywords: equal area criterion; Lyapunov criterion; transient stability; time-domain simulation (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2021
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/14/21/7259/pdf (application/pdf)
https://www.mdpi.com/1996-1073/14/21/7259/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:14:y:2021:i:21:p:7259-:d:671241

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:14:y:2021:i:21:p:7259-:d:671241