Harmonic Mitigation in Electric Railway Systems Using Improved Model Predictive Control
Chakrit Panpean,
Kongpol Areerak,
Phonsit Santiprapan,
Kongpan Areerak and
Seang Shen Yeoh
Additional contact information
Chakrit Panpean: School of Electrical Engineering, Suranaree University of Technology, Nakhon Ratchasima 30000, Thailand
Kongpol Areerak: School of Electrical Engineering, Suranaree University of Technology, Nakhon Ratchasima 30000, Thailand
Phonsit Santiprapan: Department of Electrical Engineering, Prince of Songkla University, Songkhla 90110, Thailand
Kongpan Areerak: School of Electrical Engineering, Suranaree University of Technology, Nakhon Ratchasima 30000, Thailand
Seang Shen Yeoh: Power Electronics, Machines and Control Group, University of Nottingham, Nottingham NG7 2RD, UK
Energies, 2021, vol. 14, issue 7, 1-16
Abstract:
An electric multiple unit (EMU) high-speed train is the dynamic load that degrades the power quality in an electric railway system. Therefore, a power quality improvement system using an active power filter (APF) must be considered. Due to the oscillating load current in the dynamic load condition, a fast and accurate harmonic current-tracking performance is required. As such, this paper proposes the design of a model predictive control (MPC) since the minimization of cost function in the MPC process can suitably determine APF switching states. The design technique of MPC is based on the APF mathematical model. This controller was designed to compensate the time delay in the digital control. Moreover, the synchronous detection (SD) method applied the reference current calculations, as shown in this paper. To verify the proposed MPC, the overall control of APF was implemented on a eZdsp F28335 board by using the hardware-in-the-loop technique. The testing results indicated that the proposed MPC can provide a fast and accurate harmonic current-tracking response compared with the proportional-integral controller. In the load changing condition, the MPC was still effective in providing a good result after compensation. The percentage of total harmonic distortion, the percentage current unbalance factor, and the power factor would also be kept within the IEEE Standard 519 and IEEE Standard 1459.
Keywords: harmonic mitigation; active power filter; synchronous detection; model predictive control; electric railway system (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://www.mdpi.com/1996-1073/14/7/2012/pdf (application/pdf)
https://www.mdpi.com/1996-1073/14/7/2012/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:14:y:2021:i:7:p:2012-:d:530513
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().