EconPapers    
Economics at your fingertips  
 

Thermal and Emission Performance Evaluation of Hydrogen-Enriched Natural Gas-Fired Domestic Condensing Boilers

Radosław Jankowski (), Rafał Ślefarski, Ireneusz Bauma and Giennadii Varlamov
Additional contact information
Radosław Jankowski: Institute of Thermal Energy, Poznan University of Technology, 60-965 Poznan, Poland
Rafał Ślefarski: Institute of Thermal Energy, Poznan University of Technology, 60-965 Poznan, Poland
Ireneusz Bauma: Institute of Thermal Energy, Poznan University of Technology, 60-965 Poznan, Poland
Giennadii Varlamov: Institute of Sustainable Building Materials and Engineering Systems, Riga Technical University, Ķīpsalas 6A-539, LV-1048 Riga, Latvia

Energies, 2025, vol. 18, issue 13, 1-15

Abstract: The combustion of gaseous fuels in condensing boilers contributes to the greenhouse gas and toxic compound emissions in exhaust gases. Hydrogen, as a clean energy carrier, could play a key role in decarbonizing the residential heating sector. However, its significantly different combustion behavior compared to hydrocarbon fuels requires thorough investigation prior to implementation in heating systems. This study presents experimental and theoretical analyses of the co-combustion of natural gas with hydrogen in low-power-output condensing boilers (second and third generation), with hydrogen content of up to 50% by volume. The results show that mixtures of hydrogen and natural gas contribute to increasing heat transfer in boilers through convection and flue gas radiation. They also highlight the benefits of using the heat from the condensation of vapors in the flue gases. Other studies have observed an increase in efficiency of up to 1.6 percentage points compared to natural gas at 50% hydrogen content. Up to a 6% increase in the amount of energy recovered by water vapor condensation was also recorded, while exhaust gas losses did not change significantly. Notably, the addition of hydrogen resulted in a substantial decrease in the emission of nitrogen oxides (NOx) and carbon monoxide (CO). At 50% hydrogen content, NO x emissions decreased several-fold to 2.7 mg/m 3 , while CO emissions were reduced by a factor of six, reaching 9.9 mg/m 3 . All measured NO x values remained well below the current regulatory limit for condensing gas boilers, which is 33.5 mg/m 3 . These results highlight the potential of hydrogen blending as a transitional solution on the path toward cleaner residential heating systems.

Keywords: condensing boiler; hydrogen; nitric oxides; flame emissivity (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2025
References: Add references at CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/18/13/3240/pdf (application/pdf)
https://www.mdpi.com/1996-1073/18/13/3240/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:18:y:2025:i:13:p:3240-:d:1683909

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-06-21
Handle: RePEc:gam:jeners:v:18:y:2025:i:13:p:3240-:d:1683909