Investigating the Impact of Integration the Saudi Code of Energy Conservation with the Solar PV Systems in Residential Buildings

Radwan A. Almasri, Abdullah A. Alardhi and Saad Dilshad
Additional contact information
Radwan A. Almasri: Department of Mechanical Engineering, College of Engineering, Qassim University, Buraydah 6666-51452, Saudi Arabia
Abdullah A. Alardhi: Department of Mechanical Engineering, College of Engineering, Qassim University, Buraydah 6666-51452, Saudi Arabia
Saad Dilshad: Department of Electrical and Computer Engineering, COMSATS University Islamabad, Islamabad 45550, Pakistan

Sustainability, 2021, vol. 13, issue 6, 1-30

Abstract: The demand for air conditioning is increasing day by day in the world’s hot and humid climate areas. Energy conservation in buildings can play a vital role in meeting this high cooling demand. This paper attempts to consider the impacts of energy efficiency and renewable energy measures on the energy demand of Saudi Arabia’s residential buildings. The energy analysis and economic feasibility analysis of thermal insulations are performed in this paper by investigating the effect of residential buildings’ thermal insulations on the economic feasibility of grid-connected photovoltaic systems. This was the combined effort of building owners and government, and buildings were examined if a photovoltaic system and thermal insulation were used. The study was conducted in the three climate zones in Saudi Arabia. The results showed that the building base case’s annual electrical energy consumption in Riyadh city was 67,095 kWh, Hail 57,373 kWh, and Abha 26,799 kWh. For the basic case-building in Riyadh, 69% of the total electrical energy was used for cooling and heating. Applying the Saudi Building Code requirement for Riyadh will provide only 18% of the total energy used for cooling and heating. RETScreen 6.1 software was used to design a photovoltaic system; the analysis was done using technical and economic indicators. The annual yield factor for Riyadh, Hail, and Abha was 1649 kWh/kWp/year, 1711 kWh/kWp/year, and 1765 kWh/kWp/year, respectively. The capacity factors for Riyadh, Hail, and Abha were 18.8%, 19.5%, and 20.1%, respectively. The Unified photovoltaic Levelized energy costs were 0.031, 0.030, and 0.029 $/kWh for Riyadh, Hail, and Abha, respectively. Finally, the Net Present Value and greenhouse gas emissions reduction have been estimated.

Keywords: thermal insulation; residential building; SBC-602; energy efficiency; solar energy; sustainable; KSA (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (2)

Downloads: (external link)
https://www.mdpi.com/2071-1050/13/6/3384/pdf (application/pdf)
https://www.mdpi.com/2071-1050/13/6/3384/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:13:y:2021:i:6:p:3384-:d:520000

Access Statistics for this article

Sustainability is currently edited by Ms. Alexandra Wu

More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jsusta:v:13:y:2021:i:6:p:3384-:d:520000