EconPapers    
Economics at your fingertips  
 

Concentration-Temporal Multilevel Calibration of Low-Cost PM 2.5 Sensors

Rong-Fuh Day, Peng-Yeng Yin (), Yuh-Chin T. Huang, Cheng-Yi Wang, Chih-Chun Tsai and Cheng-Hsien Yu
Additional contact information
Rong-Fuh Day: Department of Information Management, National Chi Nan University, No. 1, University Rd., Puli 545, Nantou County, Taiwan
Peng-Yeng Yin: Information Technology and Management Program, Ming Chuan University, No. 5 De Ming Rd., Taoyuan City 333, Gui Shan District, Taiwan
Yuh-Chin T. Huang: Department of Medicine, Duke University Medical Center, 10 Duke Medicine Circle, Durham, NC 27710, USA
Cheng-Yi Wang: Department of Internal Medicine, Cardinal Tien Hospital and School of Medicine, College of Medicine, Fu Jen Catholic University, New Taipei City 231, Taishan District, Taiwan
Chih-Chun Tsai: Department of Information Management, National Chi Nan University, No. 1, University Rd., Puli 545, Nantou County, Taiwan
Cheng-Hsien Yu: Department of Information Management, China University of Technology, No. 56, Sec. 3, Xinglong Rd., Taipei City 116, Wunshan District, Taiwan

Sustainability, 2022, vol. 14, issue 16, 1-12

Abstract: Ambient aerosols have a significant impact on plant species mortality, air pollution, and climate change. It is critical to monitor the concentrations of aerosols, especially particulate matter with an aerodynamic diameter ≤ 2.5 μm (PM 2.5 ), which has a direct relationship with human respiratory diseases. Recently, low-cost PM 2.5 sensors have been deployed to provide a denser monitoring coverage than that of government-built monitoring supersites, which only give a macro perspective of air quality. To increase the measurement accuracy, low-cost sensors need to be calibrated. In current practice, regression techniques are used to calibrate sensors. This paper proposes a concentration-temporal multilevel calibration method to cope with the varying regression relation in different concentration and temporal domains. The performance of our method is evaluated with real field data from a supersite sensor and a low-cost sensor deployed in Puli, Taiwan. The experimental results show that our calibration method significantly outperforms linear regression in terms of R 2 , Root Mean Square Error, and Normalized Mean Error. Moreover, our method compares favorably with a machine learning calibration method based on gradient regression tree boosting.

Keywords: PM 2.5; supersite sensor; low-cost sensor; multilevel calibration; linear regression (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2022
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/2071-1050/14/16/10015/pdf (application/pdf)
https://www.mdpi.com/2071-1050/14/16/10015/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:14:y:2022:i:16:p:10015-:d:887057

Access Statistics for this article

Sustainability is currently edited by Ms. Alexandra Wu

More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jsusta:v:14:y:2022:i:16:p:10015-:d:887057