EconPapers    
Economics at your fingertips  
 

Faulty Feeder Detection Based on Grey Correlation Degree of Adaptive Frequency Band in Resonant Grounding Distribution System

Yanwen Wang, Jiyuan Cao (), Zhiming Hu, Xueqian Han and Xuan Zhou
Additional contact information
Yanwen Wang: School of Mechanical, Electronic & Information Engineering, China University of Mining and Technology-Beijing, Beijing 100083, China
Jiyuan Cao: School of Mechanical, Electronic & Information Engineering, China University of Mining and Technology-Beijing, Beijing 100083, China
Zhiming Hu: Nanchong Power Supply Company, State Grid Sichuan Electric Power Company, Nanchong 637000, China
Xueqian Han: School of Mechanical, Electronic & Information Engineering, China University of Mining and Technology-Beijing, Beijing 100083, China
Xuan Zhou: School of Mechanical, Electronic & Information Engineering, China University of Mining and Technology-Beijing, Beijing 100083, China

Sustainability, 2023, vol. 15, issue 10, 1-16

Abstract: Due to the particularity of their process, petrochemical enterprises have high requirements for the reliability of power supply. If a large-scale blackout occurs due to a grounding fault, it will pose a huge threat to safe production. When the resonant grounding system of petrochemical enterprises faults, due to the complex fault process and weak fault signal, it is difficult to accurately detect the faulty feeder by traditional methods. This paper presents a new method of grey correlation degree based on adaptive frequency band. Firstly, the transient zero-sequence current of each feeder is decomposed by coif5 wavelet, and the low frequency band a5 (power frequency component) and high frequency band d1, d2 (noise signal) are removed. By stacking all of the remaining frequency band signals to construct the wavelet area matrix, the faulty feeder detection characteristic scale and the first faulty feeder detection result are obtained. Secondly, based on the faulty feeder detection characteristic scale, the second faulty feeder detection result is obtained by the average grey correlation degree matrix, which detects the faulty feeder according to the waveform correlation degree. Finally, the final faulty feeder detection result is obtained by equal weight voting. In MATLAB/Simulink, the 10 kV resonant grounding system of petrochemical enterprises is modeled. A large number of simulation results show that the faulty feeder detection method is not affected by the initial phase angle (0°, 45° and 90°), transition resistance (10 Ω, 100 Ω and 1000 Ω), fault distance (1 km, 8 km and 15 km) and overcompensation degree (5%, 8% and 10%), and has good sensitivity.

Keywords: faulty feeder detection; power supply safety of petrochemical enterprises; resonant grounding distribution system; adaptive frequency band; modulus maximum principle (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/2071-1050/15/10/8116/pdf (application/pdf)
https://www.mdpi.com/2071-1050/15/10/8116/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:15:y:2023:i:10:p:8116-:d:1148523

Access Statistics for this article

Sustainability is currently edited by Ms. Alexandra Wu

More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jsusta:v:15:y:2023:i:10:p:8116-:d:1148523