Predicting Contamination Spread Inside a Hospital Breakroom with Multiple Occupants Using High Fidelity Computational Fluid Dynamics Simulation on a Virtual Twin
Vijaisri Nagarajan (),
Nicolas Fougere,
Elissa M. Schechter-Perkins,
William E. Baker,
Adrien Mann,
Jonathan Jilesen and
Zaid Altawil
Additional contact information
Vijaisri Nagarajan: Dassault Systèmes, SIMULIA, 990 N Squirrel Road, Suite 100, Auburn Hills, MI 48326, USA
Nicolas Fougere: Dassault Systèmes, SIMULIA, 990 N Squirrel Road, Suite 100, Auburn Hills, MI 48326, USA
Elissa M. Schechter-Perkins: Department of Emergency Medicine, Chobanian & Avedisian School of Medicine, 72 East Concord St, Boston, MA 02118, USA
William E. Baker: Department of Emergency Medicine, University of Vermont Larner College of Medicine, UVMMC, 111 Colchester Ave, WP1—106, Burlington, VT 05401, USA
Adrien Mann: Dassault Systèmes, SIMULIA, 990 N Squirrel Road, Suite 100, Auburn Hills, MI 48326, USA
Jonathan Jilesen: Dassault Systèmes, SIMULIA, 990 N Squirrel Road, Suite 100, Auburn Hills, MI 48326, USA
Zaid Altawil: Department of Emergency Medicine, Chobanian & Avedisian School of Medicine, 72 East Concord St, Boston, MA 02118, USA
Sustainability, 2023, vol. 15, issue 15, 1-26
Abstract:
Mitigating the rise and spread of contaminants is a major challenge faced during any contagious disease outbreak. In densely occupied areas, such as a breakroom, the risk of cross-contamination between healthy and infected individuals is significantly higher, thereby increasing the risk of further spread of infectious diseases. In this study, a high fidelity transient fluid solver and Lagrangian particle-based method were used to predict the airflow distribution and contaminant transmission inside a detailed 3D virtual twin of an emergency hospital breakroom. The solver efficiently captured the contaminants emitted simultaneously from multiple talking occupants as well as their propagation inside the breakroom. The influence of airflow distribution on the aerosol spread inside the breakroom for two different air conditioning vent positions was demonstrated with all occupants and with reduced occupants. The baseline simulation with all occupants in the breakroom showed a higher risk of contamination overall as well as between adjacent occupants. It was observed that there was a 26% reduction in the contaminants received by the occupants with the proposed modified vent arrangement and a 70% reduction with the scenarios considering a reduced number of occupants. Furthermore, the fomite deposition and cross-contamination between adjacent humans significantly changed with different ventilation layouts. Based on the simulation results, areas with higher contaminant concentrations were identified, providing information for the positioning of UV lights in the breakroom to efficiently eliminate/reduce the contaminants.
Keywords: aerosols; ventilation; computational fluid dynamics (cfd); lattice Boltzmann; Lagrangian particle modeling (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/2071-1050/15/15/11804/pdf (application/pdf)
https://www.mdpi.com/2071-1050/15/15/11804/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:15:y:2023:i:15:p:11804-:d:1207896
Access Statistics for this article
Sustainability is currently edited by Ms. Alexandra Wu
More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().