Study on the Characteristics of Electromagnetic Noise of Axial Flux Permanent Magnet Synchronous Motor
Wei Wang,
Hang Wang and
Hamid Reza Karimi
Abstract and Applied Analysis, 2014, vol. 2014, 1-8
Abstract:
The normal electromagnetic force distribution in stator system of axial flux permanent magnet synchronous motor (PMSM) has been thoroughly analyzed in this paper. The main composition of force wave causing vibration and noise has been proposed, and at the same time a calculation method of stator natural frequency of axial flux PMSM has been raised. Through this method electromagnetic force wave, natural frequency, vibration response, and electromagnetic noise of a 15 kW axial flux PMSM with 22 poles and 24 slots have been calculated; calculations and measured values are consistent by comparison. The noise sources of axial flux PMSM have been found in this paper, which provides the theoretical support for the suppression of electromagnetic noise of axial flux PMSM.
Date: 2014
References: Add references at CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
http://downloads.hindawi.com/journals/AAA/2014/764105.pdf (application/pdf)
http://downloads.hindawi.com/journals/AAA/2014/764105.xml (text/xml)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:hin:jnlaaa:764105
DOI: 10.1155/2014/764105
Access Statistics for this article
More articles in Abstract and Applied Analysis from Hindawi
Bibliographic data for series maintained by Mohamed Abdelhakeem ().