EconPapers    
Economics at your fingertips  
 

Environmental Con trol of Greenhouse at Bhujodi

Pilare Vasant R and Girja Sharan

No WP1998-11-02, IIMA Working Papers from Indian Institute of Management Ahmedabad, Research and Publication Department

Abstract: This write-up contains air temperature data and preliminary analysis of cooling requirement for greenhouse at Bhujodi. Examination of the temperature data showed that night time temperatures remain high enough most of the time. Heating of the greenhouse perhaps will not be required. Day time temperatures on the other hand, remains high enough most of the time to require cooling. Forced ventilation does seem effective, but only for part of day. Evaporation cooling and misting appears necessary. Design of fan-pad system was carried out. It consists of two fans (size 24 inch and 1/3 HP) and cross fluted pad (area 5m2). Water loss is estimated to be about 1000 lit/day in the cooling system, which works out to about 10 lit/m2 of floor are per day.

Date: 1998-11-02
References: Add references at CitEc
Citations:

There are no downloads for this item, see the EconPapers FAQ for hints about obtaining it.

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:iim:iimawp:wp01561

Access Statistics for this paper

More papers in IIMA Working Papers from Indian Institute of Management Ahmedabad, Research and Publication Department Contact information at EDIRC.
Bibliographic data for series maintained by ().

 
Page updated 2025-04-16
Handle: RePEc:iim:iimawp:wp01561