Impact of Shear Connector Spacing in Composite Construction Incorporating Cold-Formed Steel Channel Lipped Section
Anis Saggaff,
Mustapha Muhammad Lawan,
Mahmood Md Tahir and
Jahangir Mirza
Review of Industrial Engineering Letters, 2016, vol. 3, issue 1, 11-18
Abstract:
Composite construction with traditional Hot Rolled Steel (HRS) sections has been known to perform much better than with Cold-Formed Steel (CFS) sections for decades; as observed by extensive rules and requirements for their design as prescribed in current design codes. There is, however, limited technical information available about the use of composite systems that incorporates the use of light gauge steel sections, despite the potentials of the system in residential and light industrial constructions. However, the composite action of CFS with an in-situ concrete, especially Self-Compacting Concrete (SCC) using bolted shear connector has not yet established. Therefore, this study attempted to investigate the behaviour of bolted shear connector used with SCC and CFS to form a composite beam system at designated longitudinal spacing. Push-out and full-scale test specimens of longitudinal spacing of 250 mm and 300 mm with bolted shear connector of grade 8.8 installed with single nut and washer on the CFS flange and beneath it were fabricated, cast and tested till failure occurred. The experimental test results shows that the bolted shear connector possessed good ultimate strength and ultimate moment capacities with an increase in the longitudinal spacing of the bolted shear connector from 250 mm and to 300 mm respectively. It was therefore concluded that, longitudinal spacing between bolted shear connectors had significantly influenced the shear connector strength capacities.
Keywords: Cold-formed steel; Composite construction; Composite beam; Bolted shear connector; Push-out test; Longitudinal spacing (search for similar items in EconPapers)
Date: 2016
References: Add references at CitEc
Citations:
Downloads: (external link)
https://archive.conscientiabeam.com/index.php/71/article/view/2647/4084 (application/pdf)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:pkp:roiele:v:3:y:2016:i:1:p:11-18:id:2647
Access Statistics for this article
More articles in Review of Industrial Engineering Letters from Conscientia Beam
Bibliographic data for series maintained by Dim Michael ().