Abstract:
Purpose: To assess prevalence, size and location of peripapillary intrachoroidal cavitations (PICCs) and their associations in a population-based sample. . Methods: The population-based Beijing Eye Study 2011 included 3468 individuals with a mean age of 64.6±9.8 years (range:50-93 years). A detailed ophthalmic examination included enhanced depth imaging of the choroid by spectral-domain optical coherence tomography and fundus photography. PICCs were defined as triangular thickening of the choroid with the base at the optic disc border and a distance between Bruch´s membrane and sclera of ≥200μm. Parapapillary large choroidal vessels were excluded. Results: Out of 94 subjects with high myopia (refractive error 26.5mm in right eyes), OCT images were available for 89 (94.7%) participants. A PICC was detected in 15 out of these 89 highly myopic subjects (prevalence:16.9±4.0%) and in none of hyperopic, emmetropic or medium myopic subgroups each consisting of 100 randomly selected subjects. Mean PICC width was 4.2±2.3 hours (30°) of disc circumference and mean length was 1363±384μm. PICCs were located most frequently (40%) at the inferior disc border. On fundus photos, a typical yellow-orange lesion was found in 8 (53%) eyes with PICCs. In binary regression analysis, presence of PICCs was significantly associated with optic disc tilting (P=0.04) and presence of posterior staphylomata (P=0.046). Conclusions: Prevalence of PICCs in the adult Chinese population was 16.9±4.0% in the highly myopic group, with no PICCs detected in non-highly myopic eyes. PICCs were located most frequently at the inferior optic disc border. Only half of the PICCs detected on OCT images showed a yellow-orange lesion on fundus photos. Presence of PICC was significantly associated only with an increased optic disc tilting and presence of posterior staphylomata, while it was not associated with axial length, refractive error or other ocular or systemic parameters.
Date: 2013
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0078743 (text/html)
https://journals.plos.org/plosone/article/file?id= ... 78743&type=printable (application/pdf)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:plo:pone00:0078743
DOI: 10.1371/journal.pone.0078743
Access Statistics for this article
More articles in PLOS ONE from Public Library of Science
Bibliographic data for series maintained by plosone ().