Whole-body dual-energy X-ray absorptiometry demonstrates better reliability than segmental body composition analysis in college-aged students
Petr Kutáč,
Václav Bunc and
Martin Sigmund
PLOS ONE, 2019, vol. 14, issue 4, 1-15
Abstract:
Dual-energy X-ray absorptiometry (DXA) is rapidly becoming more accessible and popular as a technique to monitor body composition. The reliability of DXA has been examined extensively using a number of different methodological approaches. This study sets up to investigate the accuracy of measuring the parameters of body composition (BC) by means of the whole-body and the segmental DXA method analysis with the typical error of measurement (TEM) that allows for expressing the error in the units of measure. The research was implemented in a group of 63 participants, all of whom were university students. Thirty-eight males (22.6±2.9 years, average body mass 77.5±8.4 kg) and 25 females (21.4±2.0 years, average body mass 58.6±7.2 kg) were recruited. The measured parameters included body mass (BM), fat-free mass (FFM), body fat (BF), bone mineral content (BMC), bone mineral density (BMD). For the whole-body analysis, the determined TEM was: BM at the level of 0.12 kg in females and 0.29 kg in males; BF 0.25kg and 0.44% females, 0.52 kg and 0.66% males; FFM 0.24 kg females and 0.42 kg males; BMC 0.02 kg females and males; BMD 0.01g/cm2 females and males. The TEM values in the segmental analysis were: BF within the range of 0.04–0.28 kg and 0.68–1.20% in females, 0.10–0.36 kg and 0.72–1.94% in males; FFM 0.08–0.41 kg females and 0.17–0.86 males, BMC 0.00–0.02 kg females and 0.01–0.02 kg males in relation to the body segment (upper limb, trunk, lower limb). The BMD value was at the level of 0.01–0.02g/cm2. The study results showed high reliability in measuring body composition parameters using the DXA method. The whole-body analysis showed a higher accuracy of measurement than the segmental. Only the changes that are greater than the TEM, or the upper bound (95%) of the confidence interval of the measurement can be considered demonstrable when interpreting repeated measurements.
Date: 2019
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0215599 (text/html)
https://journals.plos.org/plosone/article/file?id= ... 15599&type=printable (application/pdf)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:plo:pone00:0215599
DOI: 10.1371/journal.pone.0215599
Access Statistics for this article
More articles in PLOS ONE from Public Library of Science
Bibliographic data for series maintained by plosone ().