Reliability Analysis of Commercial Buildings Post-Certificate of Functional Reliability through Document Compliance Evaluation against Technical Standards in X Regency
Cindi Yuliani and
Aqli Mursadin
Additional contact information
Cindi Yuliani: Faculty of Engineering, Lambung Mangkurat University, Jalan Brigjen H. Hasan Basri, Banjarmasin, 70123, Indonesia
Aqli Mursadin: Faculty of Engineering, Lambung Mangkurat University, Jalan Brigjen H. Hasan Basri, Banjarmasin, 70123, Indonesia
Technium, 2026, vol. 31, 96-108
Abstract:
Abstract. The rapid economic growth in South Kalimantan has driven massive development of commercial facilities. To ensure building safety and reliability, the government mandates the possession of a Certificate of Functional Worthiness as evidence of compliance with technical standards. However, discrepancies are frequently found between administrative documents and the actual operational conditions in the field following the certificate issuance. This research aims to evaluate the compliance of technical documents for three commercial buildings in Regency X against the latest technical standards, as well as to analyze the implications of spatial function changes on structural reliability and user safety. The method employed in this study is a non-destructive visual comparative analysis. The research was conducted by juxtaposing secondary data, consisting of As-Built Drawings and technical assessment reports, against the results of observational field inspections of existing conditions. The evaluation focuses on the conformity of architectural spatial planning, the validation of structural design load assumptions resulting from functional conversion, and the reliability of fire protection systems. The results indicate significant adaptations of spatial functions in the three case studies, such as the conversion of retail areas into places of worship and the utilization of mezzanine areas inconsistent with the initial plan. These changes result in discrepancies between the live load assumptions and safety requirements stated in the documents compared to the actual conditions. Based on these findings, the building functionality status is categorized as Conditionally Eligible, requiring the owner to undertake Corrective Actions. This study recommends the implementation of risk-based technical verification and continuous monitoring to ensure long-term building reliability.
Date: 2026
References: Add references at CitEc
Citations:
Downloads: (external link)
https://techniumscience.com/index.php/technium/article/view/13469 (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:tec:techni:ojs:13469
DOI: 10.47577/technium.v31i.13469
Access Statistics for this article
Technium is currently edited by Scurtu Ionut Cristian
More articles in Technium from Technium Science
Bibliographic data for series maintained by Ana Maria Golita ().