Radiofrequency Intensity Exposure Levels from the Digital Terrestrial Television (DTTV) Broadcasting Transmitter in Kampala Metropolitan; Uganda
Peter Opio,
Akisophel Kisolo,
Willy Okullo,
Gertrude Ayugi,
Bobrich Mwecumi Muhereza and
Tumps Ireeta
Additional contact information
Peter Opio: College of Natural Science, Department of Physics, Makerere University
Akisophel Kisolo: College of Natural Science, Department of Physics, Makerere University
Willy Okullo: College of Natural Science, Department of Physics, Makerere University
Gertrude Ayugi: College of Natural Science, Department of Physics, Makerere University
Bobrich Mwecumi Muhereza: Faculty of Business Administration and Management, Ndejje University
Tumps Ireeta: College of Natural Science, Department of Physics, Makerere University
Technium, 2021, vol. 3, issue 3, 1-12
Abstract:
In this paper, we present the investigation in the radiofrequency intensity exposure levels from the DTTV broadcasting transmitters in, Nakulabye residential area, Mulago Hospital, Physics Department of Makerere University and Kyambogo Senior Secondary School, all in Kampala metropolitan. The DTTV frequency bands considered in this study were the sub 700MHz (474MHz-694MHz) and the 700 MHz (694 MHz-790 MHz) frequency bands. Investigation was done for three constant days in each of the Measurement Locations (MLos) using the Aaronia Spectran HF-6065 V4 spectrum analyzer, Aaronia AG HyperLOG 4025 Antenna, Aaronia GPS Logger, real time Aaronia MCS spectrum-analysis-software and a T430s Lenovo Laptop. In all these MLos, the mean daily and projected monthly exposure levels ranged from 0.00049 µW/m2/day to 0.002542 µW/m2/day and from 0.00495µW/m2/month to 0.02410 µW/m2/month in the sub 700 MHz frequency band while as in the 700 MHz frequency band, it ranged from 0.00076 µW/m2/day to 0.00209 µW/m2/day and from 0.00769 µW/m2/month to 0.07944 µW/m2/month. The results of this study show that the maximum exposure levels are very low when compared with the recommended International Commission on Non-Ionizing Radiation Protection (ICNIRP) safety RF intensity exposure level limits.
Date: 2021
References: Add references at CitEc
Citations:
Downloads: (external link)
https://techniumscience.com/index.php/technium/article/view/3160 (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:tec:techni:ojs:3160
Access Statistics for this article
Technium is currently edited by Scurtu Ionut Cristian
More articles in Technium from Technium Science
Bibliographic data for series maintained by Ana Maria Golita ().