EconPapers    
Economics at your fingertips  
 

Performance of manual hyperinflation: consistency and modification of the technique by intensive care unit nurses during physiotherapy

Diane M Dennis, Christine N Duncan, Mary Pinder, Charley A Budgeon and Wendy J Jacob

Journal of Clinical Nursing, 2016, vol. 25, issue 15-16, 2295-2304

Abstract: Aims and objectives To assess the consistency and safety of manual hyperinflation delivery by nurses of variable clinical experience using a resuscitator bag during physiotherapy treatment. Background Manual hyperinflation involves the delivery of larger than normal gas volumes to intubated patients and is routinely used by nurses in collaboration with physiotherapists for the management of retained sputum. The aim is to deliver slow deep breaths with an inspiratory hold without unsafe airway pressures, lung volumes or haemodynamic changes. In addition, nursing staff should be able to ‘feel' differences in resistance and adjust their technique accordingly. Design Prospective observational study utilising the simulation of a mechanically ventilated patient. Methods Thirty‐three nurses delivered manual hyperinflation to a SimMan3G mannequin who had three distinct lung scenarios applied (normal; asthma; Acute Respiratory Distress Syndrome) in randomised order during simulated physiotherapy treatment. Respiratory rate, tidal volume (Vt), mean inspiratory flow rate (Vt/Ti), and peak airway pressure data were generated. Results Over all scenarios, mean respiratory rate = 12·3 breaths/minute, mean Vt = 638·6 mls, mean inflation time = 1·3 seconds and peak airway pressure exceeded 40 cm H2O in 41% of breaths, although only in 10% of breaths during the ‘normal' lung scenario. Conclusions Experienced nurses were able to manually hyperinflate ‘normal' patients in a simulated setting safely. Despite their knowledge of barotrauma, unsafe airway pressures were delivered in some scenarios. Relevance to clinical practice Training with regard to safe airway pressures, breath hold and adequate volumes is recommended for all nurses undertaking the procedure. Nurses and physiotherapists must closely monitor the patient's condition during manual hyperinflation thereby recognising changes with regard to lung compliance and airway resistance, with nurses responding by altering their technique. The addition of a pressure manometer in the circuit may improve patient safety when performing manual hyperinflation.

Date: 2016
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://doi.org/10.1111/jocn.13190

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:wly:jocnur:v:25:y:2016:i:15-16:p:2295-2304

Access Statistics for this article

More articles in Journal of Clinical Nursing from John Wiley & Sons
Bibliographic data for series maintained by Wiley Content Delivery ().

 
Page updated 2025-03-20
Handle: RePEc:wly:jocnur:v:25:y:2016:i:15-16:p:2295-2304