Residential carbon monoxide detector failure rates in the United States
T.J. Ryan and
K.J. Arnold
American Journal of Public Health, 2011, vol. 101, issue 10, e15-e17
Abstract:
There are more than 38 million residential carbon monoxide detectors installed in the United States. We tested 30 detectors in use and found that more than half failed to function properly, alarming too early or too late. Forty percent of detectors failed to alarm in hazardous concentrations, despite outward indications that they were operating as intended. Public health professionals should consider community education concerning detector use and should work with stakeholders to improve the reliability and accuracy of these devices.
Date: 2011
References: Add references at CitEc
Citations:
Downloads: (external link)
http://hdl.handle.net/10.2105/AJPH.2011.300274
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:aph:ajpbhl:10.2105/ajph.2011.300274_7
DOI: 10.2105/AJPH.2011.300274
Access Statistics for this article
American Journal of Public Health is currently edited by Alfredo Morabia
More articles in American Journal of Public Health from American Public Health Association
Bibliographic data for series maintained by Christopher F Baum ().