EconPapers    
Economics at your fingertips  
 

Comparison between evaporative cooling and a heat pipe assisted thermal loop for a commercial wind tower in hot and dry climatic conditions

John Kaiser Calautit, Hassam Nasarullah Chaudhry, Ben Richard Hughes and Saud Abdul Ghani

Applied Energy, 2013, vol. 101, issue C, 740-755

Abstract: Increasing focus on reducing energy consumption has raised public awareness of renewable energy resources, particularly the integration of natural ventilation devices in buildings such as wind towers. The purpose of this paper was to compare the traditional evaporative wind tower technique with a proposed wind tower system consisting of heat pipes. Computational Fluid Dynamics (CFD) was used to develop a numerical model of a wind tower system and simulate the air flow pattern around and through the device. A baseline heat exchanger section containing cylindrical heat pipes was constructed to simulate the multiphase flow behaviour of two-phase heat pipe working fluids including water and ethanol. Heat transfer rate was obtained at 113 and 106W for water and 72 and 116W for ethanol respectively. The second part of the study incorporated the cylindrical heat pipes within the control domain of a roof-mounted wind tower, highlighting the potential to achieve minimal restriction in the external air flow stream while ensuring maximum contact time, thus optimizing the cooling duty of the device. A comparison was established with the conventional evaporative cooling methodology. The proposed cooling system consisting of heat pipes was capable of reducing the air temperatures by 12–15K, depending on the configuration and operating conditions. The technology presented here is subject to IP protection under the QNRF funding guidelines.

Keywords: CFD; Evaporative cooling; Multiphase; Transient; Volume fraction; Wind tower (search for similar items in EconPapers)
Date: 2013
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (28)

Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0306261912005569
Full text for ScienceDirect subscribers only

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:eee:appene:v:101:y:2013:i:c:p:740-755

Ordering information: This journal article can be ordered from
http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/bibliographic
http://www.elsevier. ... 405891/bibliographic

DOI: 10.1016/j.apenergy.2012.07.034

Access Statistics for this article

Applied Energy is currently edited by J. Yan

More articles in Applied Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().

 
Page updated 2025-03-19
Handle: RePEc:eee:appene:v:101:y:2013:i:c:p:740-755