Abstract:
Air-cooled condenser in power plants takes a risk of freezing in extremely cold days, so it is of benefit to the safe and economical operation of direct dry cooling system to propose the anti-freezing principles and take measures. On the basis of the heat load balance between the exhaust steam and cooling air, the heat load capacity matching principle for the anti-freezing of air-cooled condenser is proposed with reference to the freezing point of water. By applying heat exchanger model to the finned tube bundles of air-cooled condenser, the thermo-aerodynamic behavior of cooling air, the condensation of exhaust steam and the sensible heat rejection of condensate in a representative air-cooled condenser cell are synchronously modeled and resolved. The correlations among the ambient temperature, flow rate of cooling air, exhaust steam flow rate and quality, and back pressure of turbine that prevent the air-cooled condenser from freezing are discussed, and the anti-freezing flow rate of exhaust steam, back pressure of turbine and flow rate of axial flow fan are obtained. The results show that the anti-freezing flow rate of exhaust steam and back pressure both increase with decreasing the ambient temperature and increasing the flow rate of axial flow fan, from which derive the secure steam flow rate that can reduce the back pressure as much as possible to improve thermal efficiency. The anti-freezing fan flow rate increases with increasing the exhaust steam flow rate and ambient temperature, but varies little with back pressure. The increased steam quality will result in a higher heat load at the steam side, which allows a higher rotational speed of fan to be free of freezing for air-cooled condenser. The application of heat load capacity matching principle to the anti-freezing of air-cooled condenser contributes to the secure and optimal operation of dry cooling system in power plants.
Keywords: Air-cooled condenser; Heat load capability; Anti-freezing; Back pressure; Ambient temperature; Axial flow fan (search for similar items in EconPapers)
Date: 2014
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (2)
Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0306261914003778
Full text for ScienceDirect subscribers only
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:eee:appene:v:127:y:2014:i:c:p:34-43
Ordering information: This journal article can be ordered from
http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/bibliographic
http://www.elsevier. ... 405891/bibliographic
DOI: 10.1016/j.apenergy.2014.04.025
Access Statistics for this article
Applied Energy is currently edited by J. Yan
More articles in Applied Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().