A novel defrosting method using heat energy dissipated by the compressor of an air source heat pump
Zhang Long,
Dong Jiankai,
Jiang Yiqiang and
Yao Yang
Applied Energy, 2014, vol. 133, issue C, 111 pages
Abstract:
When an air source heat pump (ASHP) unit is used for space heating at low ambient temperatures in winter, frost may form on its outdoor coil surface. Since the accumulated frost adversely affects its performance and energy efficiency, periodic defrosting of the outdoor coil is necessary. Currently, the reverse-cycle defrosting (RCD) method is widely used for the defrosting of ASHP. However, this operation interrupts space heating during the defrosting process. A time lag occurs to resume heating at end of the defrosting cycle. Moreover, frequent reversing of the 4-way valve may cause mass leakage of the refrigerant, even make the system unsafe. Furthermore, some amount of heat is dissipated to the atmosphere through the compressor casing. To improve the defrosting process and use this waste heat, a novel ASHP unit is developed. The space is heated during the defrosting process using the heat dissipated by the compressor. Experiments using both the RCD method and the novel reverse cycle defrosting (NRCD) method developed in this study are conducted on an ASHP unit of 8.9kW nominal heating capacity. The experimental results indicated that in the NRCD method, the discharge and suction pressures are increased by 0.33MPa and 0.14MPa, respectively, the defrosting time is shortened by 65% while the resuming heating period vanished with the NRCD method, and that the total energy consumption in comparison to RCD method is reduced by 27.9% during the period which is composed of defrosting period and resuming heating period. Moreover, the NRCD method ensured continuous heating during defrosting. The mean temperature difference between the air entering and leaving the indoor coil reaches 4.1°C during defrosting. Over a test period of 125min, compared to RCD method, the total heating capacity and input power are increased by 14.2% and 12.6%, respectively. The increase in the system COP is 1.4%.
Keywords: Air source heat pump; Defrosting; Continuous heating; Dissipated heat of compressor; Thermal energy storage (search for similar items in EconPapers)
Date: 2014
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (7)
Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0306261914007211
Full text for ScienceDirect subscribers only
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:eee:appene:v:133:y:2014:i:c:p:101-111
Ordering information: This journal article can be ordered from
http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/bibliographic
http://www.elsevier. ... 405891/bibliographic
DOI: 10.1016/j.apenergy.2014.07.039
Access Statistics for this article
Applied Energy is currently edited by J. Yan
More articles in Applied Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().