Multi-objective optimization of geometrical parameters of corrugated-undulated heat transfer surfaces
Limin Wang,
Lei Deng,
Chenglong Ji,
Erkai Liang,
Changxia Wang and
Defu Che
Applied Energy, 2016, vol. 174, issue C, 25-36
Abstract:
To achieve a maximum heat transfer capability and a minimum pumping power for corrugated-undulated (CU) heat transfer surfaces, a multi-objectives genetic algorithm was used to obtain the optimal values of the pitch and height of undulated plate (U-plate) and the height of the corrugated plate (C-plate) by using the Pareto optimal strategy. For this purpose, computational fluid dynamics (CFD) simulation, support vector machine (SVM) and the fast non-dominated sorting genetic algorithm were combined together and used for the optimization process. Three dimensional numerical simulations were performed to investigate the effect of geometrical parameters on the thermos-hydraulic performance of CU heat transfer surface. The maximum deviation for the Nusselt number and friction factor between the simulation and the published data were 8.81% and 13.1% respectively when the Reynolds number ranged from 1500 to 10,000. The flow and temperature profile in the CU passage were analyzed. Intensive secondary flows occurred in the C-plate channel and the U-plate channel due to the drag effect between the main flows in the two channels. And the effects of Reynolds number and structure parameters were studied. The change of U-plate height rather than that of U-plate pitch would have a dominant effect on the disturbance influence of U-plate. Besides, two SVM models were trained by the CFD results to predict the Nusselt number and friction factor of flow in CU passages with different geometrical and operational parameters. The comparison between the SVM predictions and the CFD results showed that the SVM models could predict the numerical data with a good accuracy. In addition, two evaluation criteria were proposed from perspectives of the manufacturers and the users, respectively. Finally, a set of optimized solutions were obtained. The optimal values of pumping power ratio and heat transfer area ratio between different CU passages and the standard one were in the range of 0.8–3.1 and 0.5–1.2, respectively. The manufacturers and the users can select the best design points according to their considerations.
Keywords: Corrugated-undulated surfaces; Heat transfer; Computational fluid dynamics; Performance evaluation criteria; Support vector machine; Multi-objective genetic algorithms (search for similar items in EconPapers)
Date: 2016
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (3)
Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0306261916305402
Full text for ScienceDirect subscribers only
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:eee:appene:v:174:y:2016:i:c:p:25-36
Ordering information: This journal article can be ordered from
http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/bibliographic
http://www.elsevier. ... 405891/bibliographic
DOI: 10.1016/j.apenergy.2016.04.079
Access Statistics for this article
Applied Energy is currently edited by J. Yan
More articles in Applied Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().