EconPapers    
Economics at your fingertips  
 

Applying a magnetic field on liquid line of vapour compression system is a novel technique to increase a performance of the system

Pralhad Tipole, A. Karthikeyan, Virendra Bhojwani, Abhay Patil, Ninad Oak, Amal Ponatil and Palash Nagori

Applied Energy, 2016, vol. 182, issue C, 376-382

Abstract: This paper presents experimental investigations carried out to study the effect of magnetic field on energy savings in vapour compression system. Application of magnetic field to fluid flow breaks the molecule resulting in a decrease in the viscosity of the fluid. This drop in the viscosity reduces the pumping power required by the compressor as well as enhances the heat transfer rates in the condenser and evaporator due to increased mass flow rates. The net impact is improvement in the COP of the system. Considering the number of refrigerator and air conditioning systems sold globally every year any improvement in the COP could considerably save the energy bills as well as the energy requirement. The main benefit of this investigation is improvement in the system performance improvement in Evaporator capacity or drops in compressor power or increased COP at no cost i.e. no additional input energy. Only cost involved is the initial cost of magnets to be procured for applying suitable magnetic field. The present work was focused on first establishing the effect of magnetic field on the performance of the vapour compression system and then investigating the impact of magnetic-field strength on COP. The magnetic field strength was varied by increasing the number of magnet pairs applied to the liquid line (from condenser outlet to entry of expansion valve). The COP was initially measured without application of magnetic field, and then magnetic field applied to liquid refrigerant was increased by increasing the number of the magnetic pair from 1 to 5. The strength of each magnetic pair was 3000gauss. The result obtained showed improvement in COP of the system under investigation. The COP of the system increased up to13.13% for R134a and 21.87% for R600a refrigerant.

Keywords: Magnetic field; Hydrocarbon refrigerants; Refrigeration effect; Compressor power consumption; COP (search for similar items in EconPapers)
Date: 2016
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0306261916312296
Full text for ScienceDirect subscribers only

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:eee:appene:v:182:y:2016:i:c:p:376-382

Ordering information: This journal article can be ordered from
http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/bibliographic
http://www.elsevier. ... 405891/bibliographic

DOI: 10.1016/j.apenergy.2016.08.129

Access Statistics for this article

Applied Energy is currently edited by J. Yan

More articles in Applied Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().

 
Page updated 2025-03-19
Handle: RePEc:eee:appene:v:182:y:2016:i:c:p:376-382