Anthracite combustion characteristics and NOx formation of a 300MWe down-fired boiler with swirl burners at different loads after the implementation of a new combustion system
Zhichao Chen,
Qingxiang Wang,
Bingnan Wang,
Lingyan Zeng,
Miaomiao Che,
Xin Zhang and
Zhengqi Li
Applied Energy, 2017, vol. 189, issue C, 133-141
Abstract:
A new combustion system has been applied to a 300MWe down-fired boiler with swirl burners to reduce NOx emissions. The unit provided the introduction of overfire air (OFA) and a decrease in the flow area of the inner and outer secondary air ducts of the swirl burners. Industrial experiments on the retrofitted boiler were performed at different loads. Full-scale measurements of the flue gas temperature distribution in the burner outlet region, the furnace temperature distributions measured by a pyrometer and the local mean gas species concentrations in the region near the sidewall were made at loads of 180, 250, and 300MWe. The results show that the ignition distance increased with decreasing load, especially as the load decreased from 250MWe to 180MWe. At three different loads, the retrofitted coal/air flow could be all ignited in time at a distance in the range of 0.6–1.4m from the burner outlet. Compared with the original combustion system, the ignition distance of the coal/air flow was significantly reduced at a load of 300MWe. In addition, at a load of 300MWe, the temperature of the boiler hopper was much higher than that at loads of 180MWe and 250MWe. Compared with the original combustion system, the upper furnace temperature decreased slowly with increasing measurement height at a load of 300MWe after the retrofit. Measurements of the O2 and CO concentrations in the region near the sidewall indicate that the fullness degree of the coal flame in the furnace at different loads was different. After the retrofit, the reheat steam temperatures reached the design temperature of 541°C at loads of 180MWe and 250MWe, and the average reheat steam temperatures increased by approximately 13°C. Compared with the original combustion system, a significant NOx reduction (more than 40%) at different loads was achieved without increasing the levels of unburnt carbon in the fly ash.
Keywords: Down-fired boiler; Swirl burner; Overfire air; Load; Pulverized coal combustion; NOx emissions (search for similar items in EconPapers)
Date: 2017
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (15)
Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0306261916318268
Full text for ScienceDirect subscribers only
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:eee:appene:v:189:y:2017:i:c:p:133-141
Ordering information: This journal article can be ordered from
http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/bibliographic
http://www.elsevier. ... 405891/bibliographic
DOI: 10.1016/j.apenergy.2016.12.063