Dynamic 3D volume element model of a parabolic trough solar collector for simulation and optimization
S. Yang,
T.S. Sensoy and
J.C. Ordonez
Applied Energy, 2018, vol. 217, issue C, 509-526
Abstract:
This paper presents a dynamic three-dimensional volume element model of a parabolic trough solar collector coupled to an existing semi-finite optical model for simulation and optimization. The spatial domain in the volume element model is discretized with lumped control volumes (i.e., volume elements) in cylindrical coordinates according to the predefined collector geometry. The spatial dependency of the model is therefore taken into account without the need to solve partial differential equations. The proposed model combines the laws of thermodynamics and heat transfer as well as empirical correlations to simplify the modeling and expedite the computations, and the resulting system of ordinary differential equations is integrated in time for temperature. The model was validated with the experimental data provided in the literature, and was employed to evaluate the sensitivity of the collector performance described by the first and second law efficiencies to receiver length, annulus gap spacing, concentration ratio, incidence angle, inlet fluid temperature and flow rate. This work also examined the effects of inlet fluid temperature and temperature differential on dynamic collector performance in the transient case study. Results showed that the first law efficiency was most sensitive to the inlet fluid temperature with the maximum variation of 30%, whereas the incidence angle and concentration ratio affected the second law efficiency the most with the maximum variations of 375% and 300%, respectively. The remaining parameters featured trivial effects in all cases. In the transient analysis, higher temperature differential and lower inlet fluid temperature yielded higher total heat gain while the total exergy gain was insensitive to both parameters. The first law efficiency should therefore be of greater importance than the second law efficiency in the control of dynamic collector performance based on these two parameters.
Keywords: Dynamic solar collector simulation; Parabolic trough collector; Sensitivity analysis; Volume element model (search for similar items in EconPapers)
Date: 2018
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (12)
Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0306261918302241
Full text for ScienceDirect subscribers only
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:eee:appene:v:217:y:2018:i:c:p:509-526
Ordering information: This journal article can be ordered from
http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/bibliographic
http://www.elsevier. ... 405891/bibliographic
DOI: 10.1016/j.apenergy.2018.02.099
Access Statistics for this article
Applied Energy is currently edited by J. Yan
More articles in Applied Energy from Elsevier