EconPapers    
Economics at your fingertips  
 

Energy consumption analysis of residential swimming pools for peak load shaving

Chunhe Song, Wei Jing, Peng Zeng, Haibin Yu and Catherine Rosenberg

Applied Energy, 2018, vol. 220, issue C, 176-191

Abstract: Peak load shaving is a very important issue, however, most of peak load shaving methods either require extra investments or reduce the comfort of the consumers. This paper analyzes the impact of circulating pumps of residential swimming pools on the peak load, and shows that shifting the active time of circulating pumps of residential swimming pools could shave the peak load without requiring extra investments or reducing the comfort of the consumers. First, based on an extensive dataset containing hourly energy consumption readings of 1005 residents during March 2011 and October 2012 in South Ontario, this paper analyzes the features of the energy consumptions of residents with and without swimming pools. Second, this paper proposes a novel non-intrusive appliance load monitoring method to estimate the energy consumption of circulating pumps of residential swimming pools. The advantages of the proposed method are that, compared with other non-intrusive appliance load monitoring methods, it does not require high sampling rate data or prior information of the appliance, therefore the cost of implementation is reduced and users’ privacy is protected. Finally, this paper shows that, the average hourly energy consumption of CPRSP is 0.7429 kW h. During the peak hour, circulating pumps of residential swimming pools contributes 20.11% energy consumption of residents with swimming pools, as well as 8.79% peak load of all neighborhoods. When considering minimizing the peak load, by postponing circulating pumps of residential swimming pools for 8 h rather than turn them off, the peak load can be shaved by 4.64%. When considering minimizing the cost of circulating pumps of residential swimming pools, the peak load can be shaved by 3.15% by postponing circulating pumps of residential swimming pools for 6 h, meanwhile the peak hour is postponed from 18:00 to 19:00.

Keywords: Energy disaggregation; Residential swimming pool; Circulating pump; Peak load shifting (search for similar items in EconPapers)
Date: 2018
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (8)

Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0306261918304276
Full text for ScienceDirect subscribers only

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:eee:appene:v:220:y:2018:i:c:p:176-191

Ordering information: This journal article can be ordered from
http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/bibliographic
http://www.elsevier. ... 405891/bibliographic

DOI: 10.1016/j.apenergy.2018.03.094

Access Statistics for this article

Applied Energy is currently edited by J. Yan

More articles in Applied Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().

 
Page updated 2025-03-19
Handle: RePEc:eee:appene:v:220:y:2018:i:c:p:176-191