EconPapers    
Economics at your fingertips  
 

Power plant fuel consumption rate during load cycling

Dmitri Neshumayev, Leo Rummel, Alar Konist, Arvo Ots and Teet Parve

Applied Energy, 2018, vol. 224, issue C, 124-135

Abstract: A major challenge in the modern power system is the load cycling (ramping down and up) of thermal power plants due to the increase in electricity production from renewable power plants and other sources. The motivation for this paper is to quantify the effect of this on fuel consumption and as a result, variable costs. In this study, an experimental method for determining the fuel flow rate and corresponding power unit characteristics in a load-ramping operating regime was introduced and experimentally tested. The method is based on the static pressure drop of flue gas flowing through some convective heating surfaces of a boiler being proportional to the gas velocity, that is, in turn, proportional to the mass fuel rate. Therefore, after measuring the pressure drop during a steady-state regime, for example, in a tubular air preheater as the heat surface that is less susceptible to contamination from particle laden gas flow, and at the same time calculating the fuel mass flow rate through an indirect heat balance, the two parameters can be interrelated. The semi-empirical relationship obtained in this way can then be used for determining the actual fuel mass flow rate during transient boiler loads. The proposed method was used to determine the technical and economical characteristics of a pulverized combustion power unit utilizing oil-shale. Large-scale experiments were conducted in a high-pressure pulverized combustion steam generator TP-101, with a rated capacity of 300 MWth. The dual-boiler unit load ramping was constrained to 2.5 MWel/min. The results show that during ramping down the load to 50% maximum continuous rating, the mean fuel consumption decreased by 10%, and during ramp-up back to 100% maximum continuous rating, the mean fuel consumption increased by 14%. The total increase in fuel consumption during ramping cycle at given conditions, was approximately 4%.

Keywords: Power plant cycling; Large-scale dynamic experiments; Load cycling; Fuel consumption; Boiler transient operation (search for similar items in EconPapers)
Date: 2018
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (8)

Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S030626191830624X
Full text for ScienceDirect subscribers only

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:eee:appene:v:224:y:2018:i:c:p:124-135

Ordering information: This journal article can be ordered from
http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/bibliographic
http://www.elsevier. ... 405891/bibliographic

DOI: 10.1016/j.apenergy.2018.04.063

Access Statistics for this article

Applied Energy is currently edited by J. Yan

More articles in Applied Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().

 
Page updated 2025-03-19
Handle: RePEc:eee:appene:v:224:y:2018:i:c:p:124-135