An experimental study on the operational characteristics of a direct expansion based enhanced dehumidification air conditioning system

Wenjing Chen, Ming-yin Chan, Wenbing Weng, Huaxia Yan and Shiming Deng

Applied Energy, 2018, vol. 225, issue C, 922-933

Abstract: Once a conventional On-Off controlled single evaporator direct expansion air conditioning (A/C) system is installed, it has to be operated at different seasonal cooling load situations, and hence would have a hard time in trying to maintain the desired indoor thermal environment at all times, unless complicated and costly supplementary measures to provide variable dehumidification capacity are provided. Therefore, a novel standalone enhanced dehumidification air conditioning (EDAC) system was proposed based on multi-evaporator air conditioning technology. There were two evaporators in the proposed EDAC system, and the mass flow rates of both refrigerant and air to both evaporators can be varied. This paper reports on an experimental study on the operational characteristics of a prototype experimental EDAC system with both evaporators operated. Using the prototype experimental EDAC system, extensive experimental work has been carried out. During the experiments, constant compressor and supply fan speeds were used, but the refrigerant and air mass flow rates to both evaporators were varied, at different inlet air states to the experimental EDAC system. The experimental results demonstrated that at a fixed inlet air state, varying refrigerant and air mass flow rates to both evaporators led to outputting varied total cooling capacity (TCC) and equipment sensible heat ratio (E SHR) from the experimental EDAC system. For example, at an inlet air state of 26 °C and 50% RH, TCC varied from 4.5 kW to 5.32 kW and E SHR from 0.63 to 0.7. Furthermore, TCC and E SHR were mutually constrained within an irregular area in a TCC - E SHR diagram. Different inlet air states would result in shifted position of, or varied shape of an irregular area. Therefore, the use of the proposed EDAC system could provide variable output sensible and latent cooling capacity to deal with variable indoor space thermal load, so that achieving better indoor humidity and thus thermal control is possible with the proposed EDAC system.

Keywords: Enhanced dehumidification; Operational characteristics; Total cooling capacity; Sensible heat ratio; Experimental prototype; Variable output cooling capacity (search for similar items in EconPapers)
Date: 2018
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (3)

Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0306261918307931
Full text for ScienceDirect subscribers only

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:eee:appene:v:225:y:2018:i:c:p:922-933

Ordering information: This journal article can be ordered from
http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/bibliographic
http://www.elsevier. ... 405891/bibliographic

DOI: 10.1016/j.apenergy.2018.05.074

Access Statistics for this article

Applied Energy is currently edited by J. Yan

More articles in Applied Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().

 
Page updated 2025-03-19
Handle: RePEc:eee:appene:v:225:y:2018:i:c:p:922-933